Reggie Holt, P.E.
Federal Highway Administration
Production Year |
Number of Samples Tested |
Number of Lots Represented |
Total Lots Produced by Sika |
Acid Soluble %Cl by Weight of Cement Range |
Average Acid Soluble %Cl by Weight of Cement |
Weighted Average Acid Soluble %Cl by Weight of Cement |
2001 | 5 | |||||
2002 | 9 | 2 | 20 | 0.038-0.088 | 0.063 | 0.054 |
2003 | 20 | 5 | 22 | 0.032-0.116 | 0.076 | 0.073 |
2004 | 49 | 19 | 37 | 0.011-0.116 | 0.053 | 0.043 |
2005 | 63 | 24 | 44 | 0.010-0.224 | 0.051 | 0.048 |
2006 | 116 | 26 | 52 | 0.024-0.203 | 0.106 | 0.105 |
2007 | 25 | 6 | 23 | 0.034-0.309 | 0.130 | 0.136 |
2008 | 28 | 14 | 24 | 0.073-0.483 | 0.201 | 0.158 |
2009 | 25 | 5 | 18 | 0.018-0.360** | 0.130 | 0.127 |
2009 | 104* | 18 | 18 | 0.002-0.564 | 0.150 | 0.138 |
2010 | 14* | 1 | 1 | 0.088-0.171 | 0.107 | 0.107 |
Total | 453 | 120 | 264 | 0.002-0.564 | 0.103 | 0.093 |
Chloride Testing Data
Maximum Chloride Concentrations
https://www.fhwa.dot.gov/bridge/t514033.pdf
Sika Research | FHWA Research |
Protection Level | Chloride Concentration (% Cl- per wt. of cement) | ||||
≤ 0.08% | 0.08%< Cl- ≤0.30% | 0.30%< Cl- ≤0.50% | 0.50%< Cl- ≤0.65% | > 0.65% | |
PL-1A | No Risk |
RL 1 | RL 2 | RL 3 | RL 4 |
PL-1B | RL 1 | RL 2 | RL 3 | RL 4 | |
PL-2 & PL-3 | RL 1 | RL 2 | RL 2 | RL 4 |
Corrosion Risk Level
Structure Class |
Redundancy & Ductility Indicators | Expected Performance |
S1 | System factor (Øs) ≥ 1.10 & Pass ductility check |
A highly redundant bridge that will develop easily detectable cracking before debilitating strength loss. |
S2 | 1.10 > System factor (Øs) ≥ 1.0 & Pass ductility check |
A moderately redundant bridge that will develop easily detectable cracking before debilitating strength loss |
S3 | System factor (Øs) < 1.0 or Fail ductility check |
A bridge with limited ductility and/or redundancy. |
Structure Classification
*Undesirable inspection findings should
activate special inspection or monitoring.
Management Follow-up |
Management Follow-up Actions (FA) FA I – no additional measures needed * Undesirable inspection findings |
Reggie Holt, P.E.