Rehabilitation of Jointed Portland Cement Concrete Pavements: SPS-6, Initial Evaluation and Analysis
CHAPTER 6. STATUS ASSESSMENT OF THE SPS-6 SITES
This chapter summarizes key site information, pavement design factors, and the activities for monitoring data for each of the SPS-6 projects. The SPS-6 projects are presented in the following alphabetical order:
- Alabama (State Code: 01).
- Arizona (04).
- Arkansas (05).
- California (06).
- Illinois (17).
- Indiana (18).
- Iowa (19).
- Michigan (26).
- Missouri (29 and 29A).
- Oklahoma (40).
- Pennsylvania (42).
- South Dakota (46).
- Tennessee (47).
For each site, two tables are used. The first table summarizes key site information, such as constructed thicknesses and the number of dates for collecting monitoring data. This table shows the site and monitoring information available for each SPS-6 section. The site information section of the table includes some key information about the restoration techniques used, the pavement structure that was constructed, and significant dates for each pavement section. The monitoring information section of this table shows the number of dates for collecting monitoring data, the initial AC IRI, and the average traffic ESALs for each section.
The second table assesses whether the key site criteria for the site and monitoring data meet the expectations and general guidelines established by the LTPP program for the SPS-6 experiment. The guidelines presented in earlier chapters of this report were used to create a rating system of Yes, Almost, No, N/A, or dash (-) for each cell. A rating of "Yes" indicates that the section met the criteria, "Almost" means that the data were relatively close to meeting the established criteria, and "No" indicates that the criteria were not met. A rating of "N/A" indicates that data were not available at the time of this evaluation. A dash indicates that the cell does not apply to the criteria. For example, there is no AC thickness for bare PCC pavement and, therefore, a dash is placed in those cells.
ALABAMA
All levels of data were used to complete the summaries presented in tables 51 and 52. The information presented in table 51 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Alabama, the original construction date does not fall within the original design parameters established for the SPS-6 experiment.
Table 52 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, there was not enough information available at the time of this report to determine if the traffic and as-constructed design data requirements had been met. In addition, it appears that the monitoring requirements for the FWD and profile data for immediately after rehabilitation had not been met. It may be possible that these data had been collected, but had not yet been entered into the IMS database. Also, because this section is still relatively new, none of the long-term monitoring distress requirements had been met. It is very likely that not enough time had passed for all of the long-term monitoring activities to be collected and loaded into the IMS database. Therefore, it is anticipated that the long-term monitoring requirements will be met as these pavement sections continue to age.
Table 51. Alabama SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Wet, No Freeze | Traffic availability: None |
| Initial pavement condition: Fair | Climatic availability: None | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Comp- liance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | De- assigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | N/A | 303 | N/A | 113 | 1/1/1964 | 5/13/1998 | |
| 0602 | Minimum | O | - | - | N/A | 303 | N/A | 113 | 1/1/1964 | 5/13/1998 | |
| 0603 | Minimum | A | 102 | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
| 0604 | Minimum* | A | 102 | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/23/1998 | |
| 0605 | Maximum | A,O | - | - | N/A | 303 | N/A | 113 | 1/1/1964 | 5/18/1998 | |
| 0606 | Maximum | A,O | 102 | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
| 0607 | Crack & Seat | A | 102 | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
| 0608 | Crack & Seat | A | 203 | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
| 0661 | Rubblized | -,(1) | Variable | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
| 0662 | Rubblized | - | Variable | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
| 0663 | Rubblized | - | Variable | N/A | N/A | 303 | N/A | 113 | 1/1/1964 | 6/26/1998 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 1 | 1 | 3 | 0 | 2 | 0 | 0 | - | N/A |
| 0602 | 1 | 1 | 3 | 0 | 2 | 0 | 0 | - | N/A |
| 0603 | 1 | 1 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0604 | 1 | 1 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0605 | 1 | 1 | 3 | 0 | 2 | 0 | 0 | - | N/A |
| 0606 | 1 | 1 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0607 | 1 | 2 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0608 | 1 | 3 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0661 | 1 | 1 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0662 | 1 | 1 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
| 0663 | 1 | 1 | 3 | 0 | 1 | 0 | 1 | N/A | N/A |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Thick. mm: Thickness in mm.
Orig. Constr.: Date of original construction.
Rehab.: Date of rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
(1)= 0.61 m did not get rubblized.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
113= Fine-grained soils: sandy clay.
1 mm= .039 inch
Table 52. Design and monitoring requirements for Alabama SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 010601 | Yes | Yes | N/A | Yes | - | N/A |
| 010602 | Yes | Yes | N/A | Yes | - | N/A |
| 010603 | Yes | Yes | N/A | Yes | N/A | N/A |
| 010604 | Yes | Yes | N/A | Yes | N/A | N/A |
| 010605 | Yes | Yes | N/A | Yes | - | N/A |
| 010606 | Yes | Yes | N/A | Yes | N/A | N/A |
| 010607 | Yes | Yes | N/A | Yes | N/A | N/A |
| 010608 | Yes | Yes | N/A | Yes | N/A | N/A |
| 010601 | Yes | Yes | N/A | - | - | N/A |
| 010602 | Yes | Yes | N/A | - | - | N/A |
| 010603 | Yes | Yes | N/A | - | - | N/A |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 010601 | Yes | Yes | Yes | Yes | No | No | N/A | N/A | N/A | - | N/A |
| 010602 | Yes | Yes | Yes | Yes | No | No | N/A | N/A | N/A | - | N/A |
| 010603 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010604 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010605 | Yes | Yes | Yes | Yes | No | No | N/A | N/A | N/A | - | N/A |
| 010606 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010607 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010608 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010601 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010602 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| 010603 | Yes | Yes | Yes | Yes | No | No | N/A | - | N/A | N/A | N/A |
| Yes= Design criteria met. | N/A= Not available. | Almost= Close to meeting design criteria. |
| Dash (–)= Data do not apply to this cell. | No= Design criteria not met. | |
ARIZONA
All levels of data were used to complete the summaries presented in tables 53 and 54. The information presented in table 53 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Arizona, some of the AC and PCC thicknesses and some of the traffic ESALs do not fall within the original design parameters established for the SPS-6 experiment. The sections with negative ESAL values do not have a level E record status, and it is anticipated that these values will need to be corrected before the data can reach the level E record status.
Table 54 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, the climatic data almost meet the requirements established for the SPS-6 experiment. Only the sections with positive ESAL values meet the requirements of the experiment. Once the sections with negative ESAL values are corrected, it is expected that all of the Arizona sections will meet the ESAL requirement. In general, most of the as-constructed design data meet the SPS-6 requirements. In addition, most of the monitoring data from immediately before and after rehabilitation were collected, with the exception of the distress data for the supplemental sections immediately before rehabilitation occurred. In general, the long-term monitoring requirements were met with the exception of faulting.
Table 53. Arizona SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Dry, Freeze | Traffic availability: 4 to 9 years |
| Initial pavement condition: Poor | Climatic availability: 31 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Comp- liance | AC Overlay Thick. mm | PCC | Base | Sub- grade Type | Orig. Constr. | Rehab. | De- assigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 201 | 302,331 | 325 | 287 | 1/1/1967 | 7/12/1990 | 4/28/1995 |
| 0602 | Minimum | O | - | - | 203 | 302,307, 331 | 853 | 287 | 1/1/1967 | 7/12/1990 | 4/28/1995 |
| 0603 | Minimum | O | 102 | 102 | 211 | 302,331 | 307 | 287 | 1/1/1967 | 7/25/1990 | |
| 0604 | Minimum* | A,O | 102 | 102 | 208 | 302,331 | 274 | 287 | 1/1/1967 | 10/6/1990 | |
| 0605 | Maximum | M,O | - | - | 211 | 302,307, 331 | 851 | 215 | 1/1/1967 | 8/20/1990 | 4/28/1995 |
| 0606 | Maximum | M,O | 102 | 119 | 216 | 302,331 | 292 | 215 | 1/1/1967 | 10/6/1990 | |
| 0607 | Crack & Seat | M | 102 | 117 | 213 | 302,307, 331 | 452 | 287 | 1/1/1967 | 10/6/1990 | |
| 0608 | Crack & Seat | M | 203 | 224 | 208 | 302,307, 331 | 462 | 215 | 1/1/1967 | 10/6/1990 | |
| 0659 | Rubblized | - | Variable | 114 | 213 | 74,302, 331 | 241 | 215 | 1/1/1967 | 10/6/1990 | |
| 0660 | Crack & Seat | - | Variable | 216 | 211 | 302,331 | 284 | 215 | 1/1/1967 | 8/6/1990 | |
| 0661 | Crack & Seat | - | Variable | 114 | 213 | 302,331 | 279 | 287 | 1/1/1967 | 10/6/1990 | |
| 0662 | Crack & Seat | - | Variable | 114 | 203 | 302,307, 331 | 762 | 215 | 1/1/1967 | 10/6/1990 | |
| 0663 | Crack & Seat | - | Variable | 203-mm-PCC over 51-mm AC | 254 | 302,331 | 239 | 215 | 1/1/1967 | 8/5/1990 | |
| 0664 | No Maint. | - | Variable | 152 | 201 | 302,331 | 315 | 287 | 1/1/1967 | 12/4/1992 | |
| 0665 | Crack & Seat | - | Variable | 152 | 201 | 302,331 | 315 | 287 | 1/1/1967 | 12/4/1992 | |
| 0666 | Rubblized | - | Variable | 152 | 201 | 302,331 | 315 | 287 | 1/1/1967 | 12/4/1992 | |
| 0667 | Crack & Seat | - | Variable | 152 | 201 | 302,331 | 315 | 287 | 1/1/1967 | 12/4/1992 | |
| 0668 | No Maint. | - | Variable | 152 | 201 | 302,331 | 315 | 287 | 1/1/1967 | 12/4/1992 | |
| 0669 | Rubblized | - | Variable | 152 | 201 | 302,307 | 315 | 287 | 1/1/1967 | 12/4/1992 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 3 | 4 | 1 | 2 | 1 | 2 | 2 | - | 1,951,989 |
| 0602 | 4 | 5 | 1 | 2 | 1 | 2 | 2 | - | 1,588,852 |
| 0603 | 9 | 6 | 3 | 2 | 0 | 2 | 4 | 0.88 | -44,314 |
| 0604 | 9 | 6 | 3 | 2 | 0 | 2 | 4 | 0.86 | -45,642 |
| 0605 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | - | 1,596,797 |
| 0606 | 9 | 6 | 3 | 2 | 0 | 2 | 4 | 1.00 | -40,129 |
| 0607 | 9 | 6 | 3 | 2 | 0 | 2 | 4 | 0.80 | -41,554 |
| 0608 | 9 | 6 | 3 | 2 | 0 | 2 | 4 | 0.90 | -32,210 |
| 0659 | 9 | 5 | 3 | 1 | 0 | 2 | 3 | 1.06 | -258,921 |
| 0660 | 9 | 5 | 3 | 1 | 0 | 2 | 3 | 1.01 | -249,741 |
| 0661 | 9 | 5 | 3 | 1 | 0 | 2 | 3 | 0.72 | -258,921 |
| 0662 | 9 | 6 | 3 | 1 | 0 | 2 | 3 | 0.77 | -263,368 |
| 0663 | 9 | 4 | 4 | 1 | 4 | 2 | 1 | 1.44 | -505,622 |
1 mm= .039 inch
Table 54. Design and monitoring requirements for Arizona SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 040601 | Almost | Yes | Yes | Yes | - | Yes |
| 040602 | Almost | Yes | Yes | Yes | - | Yes |
| 040603 | Almost | Yes | No | Yes | Yes | Yes |
| 040604 | Almost | Yes | No | Yes | Yes | Yes |
| 040605 | Almost | Yes | Yes | Yes | - | Yes |
| 040606 | Almost | Yes | No | Yes | No | Yes |
| 040607 | Almost | Yes | No | Yes | No | Yes |
| 040608 | Almost | Yes | No | Yes | Almost | Yes |
| 040659 | Almost | Yes | No | - | - | Yes |
| 040660 | Almost | Yes | No | - | - | Yes |
| 040661 | Almost | Yes | No | - | - | Yes |
| 040662 | Almost | Yes | No | - | - | Yes |
| 040663 | Almost | Yes | No | - | - | Yes |
| 040664 | Almost | Yes | No | - | - | Almost |
| 040665 | Almost | Yes | No | - | - | Almost |
| 040666 | Almost | Yes | No | - | - | Almost |
| 040667 | Almost | Yes | No | - | - | Almost |
| 040668 | Almost | Yes | No | - | - | Almost |
| 040669 | Almost | Yes | No | - | - | Almost |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 040601 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | No | Yes- | - | Yes |
| 040602 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | No | Yes | - | Yes |
| 040603 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Almost | Yes |
| 040604 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Almost | Yes |
| 040605 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | Yes | Yes | - | Yes |
| 040606 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Almost | Yes |
| 040607 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Almost | Yes |
| 040608 | Almost | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Almost | Yes |
| 040659 | No | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040660 | No | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040661 | No | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040662 | No | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040663 | No | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | No | Yes |
| 040664 | No | No | No | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040665 | No | No | No | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040666 | No | No | No | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040667 | No | No | No | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040668 | No | No | No | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 040669 | No | No | No | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
ARKANSAS
All levels of data were used to complete the summaries presented in tables 55 and 56. The information presented in table 55 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. It should be noted that the as-constructed design data were not available in the IMS at this time. Excluding the as-constructed design data, only a few sections did not meet the design criteria for the SPS-6 experiment because of variations in rehabilitation techniques. All other design features for this section met the original design expectations for the SPS-6 experiment.
Table 56 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, the climatic data almost meet the requirements established for the SPS-6 experiment. Only the sections with positive ESAL values meet the requirements of the experiment. Once the sections with negative ESAL values are corrected, it is expected that all of the Arizona sections will meet the ESAL requirement. In general, most of the as-constructed design data meet the SPS-6 requirements. In addition, most of the monitoring data from immediately before and after rehabilitation were collected, with the exception of the distress data for the supplemental sections immediately before rehabilitation occurred. In general, the long-term monitoring requirements were met with the exception of faulting.
Table 55. Arkansas SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Wet, No Freeze | Traffic availability: None |
| Initial pavement condition: Poor | Climatic availability: 18 years | |
1 mm= .039 inch
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | O,D | - | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 12/1/1996 | |
| 0602 | Minimum | O | - | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 12/1/1996 | |
| 0603 | Minimum | O,D | 102 | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 12/17/1996 | |
| 0604 | Minimum* | A,O,D | 102 | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 10/15/1996 | |
| 0605 | Maximum | A,O | - | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 12/26/1996 | |
| 0606 | Maximum | A,O,D | 102 | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 12/11/1996 | |
| 0607 | Crack & Seat | A,(1),(2) | 102 | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 11/11/1996 | |
| 0608 | Crack & Seat | A,(1) | 203 | N/A | N/A | 339 | N/A | N/A | 1/1/1979 | 11/11/1996 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 2 | 3 | 2 | 0 | 2 | 0 | 0 | - | N/A |
| 0602 | 5 | 3 | 2 | 0 | 2 | 0 | 0 | - | N/A |
| 0603 | 4 | 2 | 2 | 0 | 1 | 0 | 0 | 0.91 | N/A |
| 0604 | 5 | 2 | 2 | 0 | 1 | 0 | 1 | 0.99 | N/A |
| 0605 | 3 | 3 | 2 | 0 | 2 | 0 | 0 | - | N/A |
| 0606 | 4 | 3 | 2 | 0 | 1 | 0 | 1 | 0.98 | N/A |
| 0607 | 5 | 2 | 2 | 0 | 1 | 0 | 0 | 1.05 | N/A |
| 0608 | 4 | 2 | 2 | 0 | 1 | 0 | 0 | 0.87 | N/A |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
(1)= Did not receive a full-depth hairline cracking pattern.
(2)= Traffic permitted on AC leveling coarse prior to placement of the AC surface coarse and cold paving joint within the section.
Table 56. Design and monitoring requirements for Arkansas SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 05A601 | Yes | Yes | N/A | No | - | N/A |
| 05A602 | Yes | Yes | N/A | Yes | - | N/A |
| 05A603 | Yes | Yes | N/A | No | N/A | N/A |
| 05A604 | Yes | Yes | N/A | No | N/A | N/A |
| 05A605 | Yes | Yes | N/A | Yes | - | N/A |
| 05A606 | Yes | Yes | N/A | No | N/A | N/A |
| 05A607 | Yes | Yes | N/A | Yes | N/A | N/A |
| 05A608 | Yes | Yes | N/A | Yes | N/A | N/A |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 05A601 | Yes | Yes | Yes | Almost | Yes | Almost | N/A | N/A | N/A | - | N/A |
| 05A602 | Yes | Yes | Yes | Almost | Yes | Almost | N/A | N/A | N/A | - | N/A |
| 05A603 | Yes | Yes | Yes | Almost | Yes | Yes | N/A | - | N/A | N/A | Yes |
| 05A604 | Yes | Yes | Yes | Almost | Yes | Yes | N/A | - | N/A | N/A | Yes |
| 05A605 | Yes | Yes | Yes | Almost | Yes | Almost | N/A | N/A | N/A | - | N/A |
| 05A606 | Yes | Yes | Yes | Almost | Yes | Yes | N/A | - | N/A | N/A | Yes |
| 05A607 | Yes | Yes | Yes | Almost | Yes | Yes | N/A | - | N/A | N/A | Yes |
| 05A608 | Yes | Yes | Yes | Almost | Yes | Yes | N/A | - | N/A | N/A | Yes |
| Yes= Design criteria met. | N/A= Not available. | Almost= Close to meeting design criteria. |
| Dash (-)= Data do not apply to this cell. | No= Design criteria not met. | |
CALIFORNIA
All levels of data were used to complete the summaries presented in tables 57 and 58. The information presented in table 57 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for California, some of the layer properties and traffic levels do not fall within the original design parameters established for the SPS-6 experiment. The sections with negative ESAL values do not have a level E record status, and it is anticipated that these values will need to be corrected before the data can reach the level E record status.
Table 58 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, the climatic requirements were not met for this site. Only the sections with positive ESAL values meet the requirements of the experiment. Once the sections with negative ESAL values are corrected, it is expected that all of the California sections will meet the ESAL requirement. In general, most of the as-constructed design data meet the SPS-6 requirements. In addition, most of the monitoring data from immediately before and after rehabilitation were collected. In general, the long-term monitoring requirements were met.
Table 57. California SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Dry, Freeze | Traffic availability: 3 to 6 years |
| Initial pavement condition: Poor | Climatic availability: None; | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | De- assigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | N/A | - | - | - | 8/1/1974 | 5/20/1992 | |
| 0602 | Minimum | O | - | - | 218 | 331 | 104 | 253 | 8/1/1974 | 5/20/1992 | |
| 0603 | Minimum | O | 102 | 97 | 203 | 331 | 102 | 253 | 8/1/1974 | 9/1/1992 | |
| 0604 | Minimum* | A,O | 102 | 114 | 211 | 331 | 130 | 253 | 8/1/1974 | 9/1/1992 | |
| 0605 | Maximum | M,O | - | - | 226 | 331 | 114 | 253 | 8/1/1974 | 5/19/1992 | |
| 0606 | Maximum | A,M | 102 | 79 | 208 | 331 | 114 | 253 | 8/1/1974 | 9/1/1992 | |
| 0607 | Crack & Seat | A | 102 | 94 | 208 | 331 | 117 | 253 | 8/1/1974 | 9/1/1992 | |
| 0608 | Crack & Seat | A | 203 | 206 | 216 | 331 | 112 | 203 | 8/1/1974 | 9/1/1992 | |
| 0659 | Crack & No Seat | - | Variable | 107 | 216 | 331 | 124 | 253 | 8/1/1974 | 8/31/1992 | |
| 0660 | Crack & Seat | - | Variable | 107 | 114 | 74,331 | 211 | 253 | 8/1/1974 | 8/30/1992 | |
| 0661 | Crack & Seat | - | Variable | 107 | 216 | 74,331 | 130 | 253 | 8/1/1974 | 8/30/1992 | |
| 0662 | Crack & Seat | - | Variable | - | 208 | 331 | 130 | 203 | 8/1/1974 | 5/26/1992 | |
| 0663 | Crack & Seat | - | Variable | AC? | 25 | 331 | 137 | 203 | 8/1/1974 | 9/1/1992 | |
| 0664 | Crack & Seat | - | Variable | 107 | 211 | 85,331 | 135 | 253 | 8/1/1974 | 9/1/1992 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | - | N/A |
| 0602 | 5 | 6 | 5 | 2 | 4 | 0 | 3 | - | 856,852 |
| 0603 | 6 | 6 | 6 | 2 | 0 | 0 | 7 | 0.85 | -437,854 |
| 0604 | 5 | 5 | 5 | 2 | 0 | 0 | 7 | 0.81 | -435,129 |
| 0605 | 5 | 5 | 3 | 2 | 3 | 0 | 3 | - | 860,924 |
| 0606 | 5 | 6 | 6 | 2 | 0 | 0 | 7 | 0.95 | -437,715 |
| 0607 | 5 | 6 | 6 | 2 | 0 | 0 | 7 | 1.01 | -436,849 |
| 0608 | 6 | 6 | 7 | 2 | 0 | 0 | 6 | 0.89 | -429,810 |
| 0659 | 5 | 4 | 4 | 1 | 0 | 0 | 4 | 0.70 | -776,938 |
| 0660 | 5 | 6 | 5 | 2 | 0 | 0 | 4 | 0.81 | -781,258 |
| 0661 | 5 | 6 | 4 | 2 | 0 | 0 | 4 | 0.83 | -776,938 |
| 0662 | 5 | 5 | 4 | 2 | 0 | 0 | 4 | - | -781,923 |
| 0663 | 5 | 5 | 4 | 2 | 4 | 0 | 1 | -? | -783,419 |
| 0664 | 7 | 5 | 7 | 2 | 0 | 0 | 5 | 0.91 | -777,602 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
203= Coarse-grained soils: poorly graded sand with gravel.
253= Coarse-grained soils: poorly graded gravel with sand.
1 mm= .039 inch
Table 58. Design and monitoring requirements for California SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 060601 | No | No | N/A | Yes | - | Yes |
| 060602 | No | No | Yes | Yes | - | Yes |
| 060603 | No | No | No | Yes | Yes | Yes |
| 060604 | No | No | No | Yes | Almost | Yes |
| 060605 | No | No | Yes | Yes | - | Yes |
| 060606 | No | No | No | Yes | No | Yes |
| 060607 | No | No | No | Yes | Almost | Yes |
| 060608 | No | No | No | Yes | Yes | Yes |
| 060659 | No | No | No | - | - | Yes |
| 060660 | No | No | No | - | - | No |
| 060661 | No | No | No | - | - | Yes |
| 060662 | No | No | No | - | - | Yes |
| 060663 | No | No | No | - | - | No |
| 060664 | No | No | No | - | - | Yes |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 040601 | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | - | N/A |
| 040602 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost |
| 040603 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040604 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040605 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost |
| 040606 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040607 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040608 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040659 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040660 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040661 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040662 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Almost |
| 040663 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | No | Almost |
| 040664 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
No= Design criteria not met.
| |
ILLINOIS
All levels of data were used to complete the summaries presented in tables 59 and 60. The information presented in table 59 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Illinois, the original construction date and some of the pavement layer properties do not fall within the original design parameters established for the SPS-6 experiment.
Table 60 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, the climate, traffic, and, in general, the as-constructed design data meet the design requirements established for the SPS-6 projects. Most of the monitoring requirements for before and after rehabilitation were met. On average, the long-term monitoring requirements were met.
Table 59. Illinois SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: Wet, Freeze | Traffic availability: 8 years |
| Initial pavement condition: Poor | Climatic availability: 17 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 259 | 302 | 178 | 113 | 4/1/1965 | 4/16/1990 | |
| 0602 | Minimum | O | - | - | 257 | 302 | 178 | 113 | 4/1/1965 | 4/16/1990 | |
| 0603 | Minimum | A | 102 | 94 | 254 | 302 | 178 | 113 | 4/1/1965 | 6/11/1990 | |
| 0604 | Minimum* | A,O | 102 | 94 | 259 | 302 | 178 | 113 | 4/1/1965 | 6/11/1990 | |
| 0605 | Maximum | A,O | - | - | 259 | 302 | 178 | 113 | 4/1/1965 | 5/18/1990 | |
| 0606 | Maximum | A,O | 102 | 79 | 257 | 302 | 178 | 113 | 4/1/1965 | 6/18/1991 | |
| 0607 | Crack & Seat | A | 102 | 94 | 257 | 302 | 178 | 113 | 4/1/1965 | 6/18/1990 | |
| 0608 | Crack & Seat | A | 203 | 173 | 257 | 302 | 178 | 113 | 4/1/1965 | 6/18/1991 | |
| 0659 | State Rehab. | - | Variable | 84 | 259 | 302 | 178 | 113 | 4/1/1965 | 6/18/1991 | |
| 0660 | Milling | - | - | - | 259 | 302 | 178 | 113 | 4/1/1965 | 5/17/1990 | |
| 0661 | Diamond Grinding | - | - | - | 267 | 302 | 178 | 113 | 4/1/1965 | 5/18/1990 | |
| 0662 | State Rehab. | - | Variable | 89 | 259 | 302 | 178 | 113 | 4/1/1965 | 6/11/1991 | |
| 0663 | Rubblized | - | Variable | 203 | 254 | 302 | 178 | 113 | 4/1/1965 | 6/18/1990 | |
| 0664 | Rubblized | - | Variable | 152 | 254 | 302 | 178 | 113 | 4/1/1965 | 6/18/1990 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 9 | 7 | 9 | 4 | 8 | 1 | 2 | - | 619,495 |
| 0602 | 8 | 7 | 8 | 4 | 8 | 1 | 2 | - | 619,495 |
| 0603 | 8 | 7 | 7 | 4 | 0 | 1 | 8 | 1.02 | 619,495 |
| 0604 | 8 | 8 | 6 | 4 | 0 | 1 | 7 | 1.13 | 619,495 |
| 0605 | 7 | 6 | 7 | 4 | 8 | 1 | 2 | - | 619,495 |
| 0606 | 8 | 7 | 7 | 4 | 0 | 1 | 7 | 1.07 | 619,495 |
| 0607 | 8 | 8 | 6 | 4 | 0 | 1 | 6 | 1.22 | 619,495 |
| 0608 | 9 | 7 | 6 | 4 | 0 | 1 | 6 | 1.16 | 619,495 |
| 0659 | 7 | 6 | 6 | 2 | 0 | 1 | 6 | 1.37 | 619,495 |
| 0660 | 7 | 6 | 45 | 2 | 5 | 1 | 2 | - | 619,495 |
| 0661 | 7 | 6 | 4 | 2 | 4 | 1 | 2 | - | 619,495 |
| 0662 | 9 | 6 | 6 | 2 | 0 | 1 | 4 | 1.10 | 619,495 |
| 0663 | 9 | 6 | 4 | 2 | 0 | 1 | 4 | 0.92 | 619,495 |
| 0664 | 8 | 6 | 3 | 2 | 0 | 1 | 3 | 1.08 | 619,495 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
113= Fine-grained soils: Sandy clay.
1 mm= .039 inch
Table 60. Design and monitoring requirements for Illinois SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 170601 | Yes | Yes | Yes | Yes | - | Almost |
| 170602 | Yes | Yes | Yes | Yes | - | Almost |
| 170603 | Yes | Yes | Yes | Yes | Almost | Yes |
| 170604 | Yes | Yes | Yes | Yes | Almost | Almost |
| 170605 | Yes | Yes | Yes | Yes | - | Almost |
| 170606 | Yes | Yes | Yes | Yes | No | Almost |
| 170607 | Yes | Yes | Yes | Yes | Almost | Almost |
| 170608 | Yes | Yes | Yes | Yes | No | Almost |
| 170659 | Yes | Yes | Yes | - | - | Almost |
| 170660 | Yes | Yes | Yes | - | - | Almost |
| 170661 | Yes | Yes | Yes | - | - | Almost |
| 170662 | Yes | Yes | Yes | - | - | Almost |
| 170663 | Yes | Yes | Yes | - | - | Yes |
| 170664 | Yes | Yes | Yes | - | - | Yes |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 170601 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | Almost | Almost | - | Yes |
| 170602 | Yes | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Almost |
| 170603 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 170604 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 170605 | Yes | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Almost |
| 170606 | Almost | Yes | Almost | Almost | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 170607 | Yes | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 170608 | Yes | Almost | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 170659 | Yes | Yes | Yes | Almost | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 170660 | Yes | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Yes |
| 170661 | Yes | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Yes |
| 170662 | Yes | Almost | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 170663 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 170664 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | Almost | Almost | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
INDIANA
All levels of data were used to complete the summaries presented in tables 61 and 62. The information presented in table 61 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Indiana, only section 180603 does not meet the original design parameters for the SPS-6 experiment because of deviations that occurred during application of the rehabilitation treatments. In addition, it should be noted that all of the material properties appear to be design values and are not based on field data. The field data should be reviewed and these fields in the database should be corrected.
Table 62 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, the climate, traffic, and most of the as-constructed design data requirements were met. It is important to note that the as-constructed design data appear to be the design values and are not currently based on field measurements. This should be addressed prior to further analysis of these pavement sections. In addition, most of the monitoring requirements for before and after rehabilitation were met. On average, the long-term monitoring requirements were also met.
Table 61. Indiana SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Wet, Freeze | Traffic availability: 3 years |
| Initial pavement condition: Poor | Climatic availability: 25 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 254 | 326 | 76 | - | 1/1/1974 | 6/11/1990 | 7/27/1993 |
| 0602 | Minimum | O | - | - | 254 | 326 | 76 | 113 | 1/1/1974 | 6/11/1990 | |
| 0603 | Minimum | O,D | 102 | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0604 | Minimum* | A,O | 102 | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0605 | Maximum | M,O | - | - | 254 | 326 | 76 | 113 | 1/1/1974 | 6/27/1990 | |
| 0606 | Maximum | A,O | 102 | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0607 | Crack & Seat | A | 102 | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0608 | Crack & Seat | A | 203 | 203 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0659 | Minimum | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0660 | Minimum | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0661 | Minimum | - | Variable | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0662 | Crack & Seat | - | Variable | 254 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0663 | Crack & Seat | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0664 | Crack & Seat | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0665 | Crack & Seat | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0666 | Crack & Seat | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0667 | Crack & Seat | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0668 | Crack & Seat | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0669 | Crack & Seat | - | Variable | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0670 | Crack & Seat | - | Variable | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0671 | Crack & Seat | - | Variable | 102 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
| 0672 | Minimum | - | Variable | 140 | 254 | 326 | 76 | 113 | 1/1/1974 | 8/30/1990 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 2 | 3 | 2 | 2 | 0 | 6 | 1 | - | 443,417 |
| 0602 | 13 | 7 | 5 | 3 | 4 | 7 | 2 | - | 443,417 |
| 0603 | 8 | 5 | 5 | 3 | 0 | 6 | 4 | 0.88 | 443,417 |
| 0604 | 9 | 6 | 7 | 4 | 0 | 7 | 7 | 0.92 | 443,417 |
| 0605 | 13 | 6 | 4 | 4 | 4 | 7 | 2 | - | 443,417 |
| 0606 | 12 | 5 | 5 | 4 | 0 | 7 | 5 | 0.94 | 443,417 |
| 0607 | 9 | 6 | 6 | 4 | 0 | 7 | 5 | 0.99 | 443,417 |
| 0608 | 10 | 6 | 5 | 4 | 0 | 7 | 5 | 0.93 | 443,417 |
| 0659 | 8 | 4 | 3 | 2 | 0 | 7 | 4 | 1.10 | 443,417 |
| 0660 | 8 | 3 | 3 | 2 | 0 | 7 | 5 | 1.10 | 443,417 |
| 0661 | 10 | 3 | 5 | 2 | 1 | 7 | 5 | 0.95 | 443,417 |
| 0662 | 11 | 5 | 4 | 2 | 0 | 7 | 5 | 0.85 | 443,417 |
| 0663 | 8 | 5 | 3 | 2 | 0 | 7 | 5 | 1.17 | 443,417 |
| 0664 | 8 | 4 | 3 | 2 | 0 | 7 | 5 | 1.15 | 443,417 |
| 0665 | 7 | 5 | 4 | 2 | 0 | 7 | 5 | 0.93 | 443,417 |
| 0666 | 7 | 5 | 3 | 2 | 0 | 7 | 5 | 0.88 | 443,417 |
| 0667 | 9 | 3 | 3 | 2 | 0 | 7 | 5 | 0.95 | 443,417 |
| 0668 | 7 | 3 | 3 | 2 | 0 | 7 | 5 | 1.07 | 443,417 |
| 0669 | 8 | 4 | 4 | 2 | 0 | 7 | 5 | 1.04 | 443,417 |
| 0670 | 8 | 4 | 4 | 2 | 0 | 7 | 5 | 1.00 | 443,417 |
| 0671 | 7 | 3 | 3 | 2 | 0 | 7 | 5 | 1.08 | 443,417 |
| 0672 | 8 | 3 | 3 | 2 | 0 | 7 | 5 | 1.10 | 443,417 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm; Orig. Constr.= Date of original construction; Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
113= Fine-grained soils: Sandy clay.
1 mm= .039 inch
Table 62. Design and monitoring requirements for Indiana SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 180601 | Yes | Yes | Yes | Yes | - | Yes* |
| 180602 | Yes | Yes | Yes | Yes | - | Yes* |
| 180603 | Yes | Yes | Yes | No | Yes* | Yes* |
| 180604 | Yes | Yes | Yes | Yes | Yes* | Yes* |
| 180605 | Yes | Yes | Yes | Yes | - | Yes* |
| 180606 | Yes | Yes | Yes | Yes | Yes* | Yes* |
| 180607 | Yes | Yes | Yes | Yes | Yes* | Yes* |
| 180608 | Yes | Yes | Yes | Yes | Yes* | Yes* |
| 180659 | Yes | Yes | Yes | - | - | Yes* |
| 180660 | Yes | Yes | Yes | - | - | Yes* |
| 180661 | Yes | Yes | Yes | - | - | Yes* |
| 180662 | Yes | Yes | Yes | - | - | Yes* |
| 180663 | Yes | Yes | Yes | - | - | Yes* |
| 180664 | Yes | Yes | Yes | - | - | Yes* |
| 180665 | Yes | Yes | Yes | - | - | Yes* |
| 180666 | Yes | Yes | Yes | - | - | Yes* |
| 180667 | Yes | Yes | Yes | - | - | Yes* |
| 180668 | Yes | Yes | Yes | - | - | Yes* |
| 180669 | Yes | Yes | Yes | - | - | Yes* |
| 180670 | Yes | Yes | Yes | - | - | Yes* |
| 180671 | Yes | Yes | Yes | - | - | Yes* |
| 180672 | Yes | Yes | Yes | - | - | Yes* |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 180601 | Yes | Yes | Yes | No | Yes | No | Yes | No | Yes | - | Yes |
| 180602 | Yes | Yes | Yes | No | Yes | Yes | Almost | Almost | Almost | - | Yes |
| 180603 | Yes | No | Yes | Almost | No | Yes | Almost | - | Almost | Yes | Yes |
| 180604 | Yes | Yes | Yes | Almost | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180605 | Yes | Yes | Yes | Almost | Yes | Yes | Almost | Almost | Almost | - | Yes |
| 180606 | Yes | No | Yes | Almost | No | Yes | Almost | - | Almost | Yes | Yes |
| 180607 | Yes | Yes | Yes | Almost | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180608 | Yes | Yes | Yes | Almost | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180659 | Yes | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 180660 | Yes | No | Yes | No | No | Yes | Almost | - | No | Yes | Yes |
| 180661 | Yes | No | Yes | No | No | Yes | Almost | - | No | Yes | Yes |
| 180662 | Yes | No | Yes | No | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180663 | Yes | Yes | Yes | No | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180664 | Yes | Yes | Yes | No | Yes | Yes | Almost | - | No | Yes | Yes |
| 180665 | Yes | Yes | Yes | No | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180666 | Yes | Yes | Yes | No | Yes | Yes | Almost | - | Almost | Yes | Yes |
| 180667 | Yes | No | Yes | No | No | Yes | Almost | - | No | Almost | Yes |
| 180668 | Yes | No | Yes | No | No | Yes | Almost | - | No | Yes | Yes |
| 180669 | Yes | No | Yes | No | No | Yes | Almost | - | Almost | Yes | Yes |
| 180670 | Yes | No | Yes | No | No | Yes | Almost | - | Almost | Yes | Yes |
| 180671 | Yes | No | Yes | No | No | Yes | Almost | - | No | Almost | Yes |
| 180672 | Yes | No | Yes | No | No | Yes | Almost | - | No | Almost | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria | Dash (-)= Data do not apply to this cell. |
Thickness information appears to be design information, not field measured as expected.
IOWA
All levels of data were used to complete the summaries presented in tables 63 and 64. The information presented in table 63 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Iowa, only a few of the design properties do not meet the original design parameters established for the SPS-6 experiment.
Table 64 summarizes the site and monitoring requirements that were and were not met based on the IMS data requirements for this project. As shown in this table, currently the climate, traffic, and most of the as-constructed design data meet the design requirements. In addition, most of the monitoring requirements for immediately before and after rehabilitation were met, with the exception of the profile immediately before rehabilitation. In general, the long-term monitoring requirements were met, with the exception of faulting.
Table 63. Iowa SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: Wet, Freeze | Traffic availability: 4 years |
| Initial pavement condition: Fair | Climatic availability: 32 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 254 | 303 | 102 | 113 | 11/1/1965 | 8/17/1989 | |
| 0602 | Minimum | O | - | - | 257 | 303 | 102 | 113 | 11/1/1965 | 8/17/1989 | |
| 0603 | Minimum | O,D | 102 | 102 | 254 | 303 | 102 | 113 | 11/1/1965 | 8/17/1989 | |
| 0604 | Minimum* | A | 102 | 117 | 246 | 303 | 102 | 113 | 11/1/1965 | 8/17/1989 | |
| 0605 | Maximum | A,O | - | - | 254 | 303 | 102 | 113 | 11/1/1965 | 8/17/1989 | |
| 0606 | Maximum | A,O | 102 | 104 | 254 | 303 | 102 | 113 | 11/1/1965 | 8/17/1989 | |
| 0607 | Crack & Seat | A | 102 | 104 | 254 | 303 | 102 | 113 | 11/1/1965 | 8/30/1989 | |
| 0608 | Crack & Seat | A | 203 | 203 | 254 | 303 | 102 | 113 | 11/1/1965 | 8/22/1989 | |
| 0659 | State Rehab. | - | Variable | 102 | 244 | 303 | 102 | 113 | 11/1/1965 | 7/20/1989 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 7 | 6 | 4 | 4 | 8 | 1 | 9 | - | 369,844 |
| 0602 | 5 | 6 | 3 | 4 | 8 | 1 | 8 | - | 371,523 |
| 0603 | 10 | 7 | 4 | 4 | 0 | 0 | 8 | 0.90 | 368,591 |
| 0604 | 10 | 7 | 4 | 4 | 0 | 0 | 8 | 1.06 | 368,591 |
| 0605 | 5 | 8 | 3 | 4 | 8 | 2 | 8 | - | 368,591 |
| 0606 | 8 | 6 | 4 | 4 | 0 | 0 | 8 | 0.92 | 368,591 |
| 0607 | 9 | 8 | 5 | 4 | 0 | 0 | 8 | 1.02 | 368,591 |
| 0608 | 10 | 8 | 5 | 4 | 0 | 0 | 8 | 1.21 | 368,591 |
| 0659 | 8 | 7 | 4 | 2 | 0 | 0 | 8 | 1.00 | 368,591 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
113= Fine-grained soils: Sandy clay.
1 mm= .039 inch
Table 64. Design and monitoring requirements for Iowa SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 190601 | Yes | Yes | Yes | Yes | - | Yes |
| 190602 | Yes | Yes | Yes | Yes | - | Almost |
| 190603 | Yes | Yes | Yes | No | Yes | Yes |
| 190604 | Yes | Yes | Yes | Yes | No | Yes |
| 190605 | Yes | Yes | Yes | Yes | - | Yes |
| 190606 | Yes | Yes | Yes | Yes | Yes | Yes |
| 190607 | Yes | Yes | Yes | Yes | Yes | Yes |
| 190608 | Yes | Yes | Yes | Yes | Yes | Yes |
| 190659 | Yes | Yes | Yes | - | - | Yes |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 190601 | Yes | Yes | No | Yes | Yes | Almost | Almost | No | Yes | - | Almost |
| 190602 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | No | Yes | - | Almost |
| 190603 | Yes | Yes | No | Yes | Yes | Almost | Almost | - | Yes | Yes | Almost |
| 190604 | Yes | Yes | No | Yes | Yes | Almost | Almost | - | Yes | Yes | Almost |
| 190605 | Yes | Yes | No | Yes | Yes | Almost | Almost | Yes | Yes | - | Almost |
| 190606 | Yes | Yes | No | Yes | No | Almost | Almost | - | Yes | Yes | Almost |
| 190607 | Yes | Yes | No | Yes | Yes | Almost | Almost | - | Yes | Yes | Almost |
| 190608 | Yes | Yes | No | Yes | Yes | Almost | Almost | - | Yes | Yes | Almost |
| 190659 | No | No | No | No | Yes | Almost | Almost | - | Yes | Yes | Almost |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
MICHIGAN
All levels of data were used to complete the summaries presented in tables 65 and 66. The information presented in table 65 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Michigan, the original construction date and most of the actual AC overlay thicknesses do not fall within the original design parameters established for the SPS-6 experiment.
Table 66 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, currently the climate, traffic, and most of the as-constructed design data, with the exception of the AC thickness, meet the design requirements for the SPS-6 experiment. In addition, most of the monitoring requirements for immediately before rehabilitation were met, while the monitoring requirements for immediately after rehabilitation were not met. On average, the long-term monitoring requirements were met.
Note that the full-depth repairs consisted of AC material rather than the PCC used at all other sites. This may have a significant impact on the performance of the rehabilitated pavement.
Table 65. Michigan SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: Wet, Freeze | Traffic availability: 8 years |
| Initial pavement condition: Fair | Climatic availability: 39 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Comp- liance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | De- assigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 229 | 201,302 | 1321 | 113 | 6/1/1958 | 5/30/1990 | |
| 0602 | Minimum | O,(1) | - | - | 229 | 201,302 | 1321 | 113 | 6/1/1958 | 5/30/1990 | |
| 0603 | Minimum | O,(1) | 102 | 103 | 229 | 201,302 | 1016 | 113 | 6/1/1958 | 5/30/1990 | |
| 0604 | Minimum* | A,O,(1) | 102 | 137 | 234 | 201,302 | 1016 | 113 | 6/1/1958 | 5/30/1990 | |
| 0605 | Maximum | M,O,(2) | - | - | 229 | 201,302 | 1321 | 113 | 6/1/1958 | 5/30/1990 | |
| 0606 | Maximum | A,O,(1) | 102 | 127 | 241 | 201,302 | 1016 | 113 | 6/1/1958 | 5/30/1990 | |
| 0607 | Crack & Seat | M | 102 | 117 | 229 | 202,302 | 1778 | 104 | 6/1/1958 | 5/30/1990 | |
| 0608 | Crack & Seat | M | 203 | 173 | 236 | 202,302 | 1321 | 104 | 6/1/1958 | 5/30/1990 | |
| 0659 | Rubblized | - | Variable | 102 | 241 | 202,302 | 864 | 104 | 6/1/1958 | 5/30/1990 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 11 | 5 | 3 | 3 | 3 | 3 | 2 | - | 345,230 |
| 0602 | 11 | 5 | 3 | 2 | 4 | 3 | 2 | - | 345,230 |
| 0603 | 12 | 6 | 5 | 2 | 0 | 3 | 7 | 1.29 | 345,230 |
| 0604 | 12 | 6 | 5 | 3 | 0 | 3 | 8 | 1.15 | 345,230 |
| 0605 | 4 | 4 | 3 | 3 | 3 | 3 | 2 | - | 345,230 |
| 0606 | 11 | 6 | 4 | 3 | 0 | 3 | 6 | 0.90 | 345,230 |
| 0607 | 11 | 6 | 4 | 3 | 0 | 3 | 7 | 1.07 | 345,230 |
| 0608 | 11 | 6 | 4 | 3 | 0 | 3 | 7 | 0.87 | 345,230 |
| 0659 | 11 | 5 | 4 | 2 | 0 | 2 | 6 | 1.14 | 345,230 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
(1)= Partial- and full-depth repairs are AC.
(2)= Partial-depth AC repairs and PCC full-depth repairs.
104= Fine-grained soils: Clay with gravel.
131= Fine-grained soils: Silty clay.
1 mm= .039 inch
Table 66. Design and monitoring requirements for Michigan SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 260601 | Yes | Yes | Yes | Yes | - | Yes |
| 260602 | Yes | Yes | Yes | Yes | - | Yes |
| 260603 | Yes | Yes | Yes | Yes | No | Yes |
| 260604 | Yes | Yes | Yes | Yes | No | Yes |
| 260605 | Yes | Yes | Yes | Yes | - | Yes |
| 260606 | Yes | Yes | Yes | Yes | No | Yes |
| 260607 | Yes | Yes | Yes | Yes | No | Yes |
| 260608 | Yes | Yes | Yes | Yes | No | Yes |
| 260659 | Yes | Yes | Yes | - | - | Yes |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 260601 | Yes | Yes | Yes | No | No | Almost | Yes | Yes | Almost | - | Yes |
| 260602 | No | Yes | Yes | No | No | Almost | Yes | Yes | Almost | - | Yes |
| 260603 | No | Yes | Yes | No | No | Almost | Almost | - | Almost | Yes | Yes |
| 260604 | Yes | Yes | Yes | No | No | Almost | Almost | - | Almost | Yes | Yes |
| 260605 | Yes | Yes | Yes | No | No | No | Yes | Yes | Almost | - | Almost |
| 260606 | Yes | Yes | Yes | No | No | Almost | Almost | - | Almost | Yes | Yes |
| 260607 | Yes | Yes | Yes | No | No | Almost | Almost | - | Almost | Yes | Yes |
| 260608 | Yes | Yes | Yes | No | No | Almost | Almost | - | Almost | Yes | Yes |
| 260659 | No | Yes | Yes | No | No | Almost | Almost | - | No | Yes | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
MISSOURI
All levels of data were used to complete the summaries presented in tables 67 and 68. The information presented in table 67 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Missouri, only a few design and traffic data do not meet the original design parameters established for the SPS-6 experiment.
Table 68 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, currently all of the climate, traffic, and as-constructed design data, with the exception of AC overlay thickness, meet the SPS-6 design parameters. In addition, most of the monitoring requirements for immediately before and after rehabilitation were met. On average, the long-term monitoring requirements were met.
Table 67. Missouri SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: Wet, Freeze | Traffic availability: 1 year |
| Initial pavement condition: Poor | Climatic availability: 17 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 231 | 303 | 107 | 113 | 10/1/1975 | 8/21/1992 | |
| 0602 | Minimum | O | - | - | 234 | 303 | 86 | 113 | 10/1/1975 | 8/21/1992 | |
| 0603 | Minimum | A | 102 | 97 | 231 | 303 | 122 | 113 | 10/1/1975 | 8/10/1992 | |
| 0604 | Minimum* | A,O | 102 | 97 | 231 | 303 | 114 | 113 | 10/1/1975 | 8/10/1992 | |
| 0605 | Maximum | A,O | - | - | 231 | 303 | 97 | 113 | 10/1/1975 | 8/21/1992 | |
| 0606 | Maximum | A,O | 102 | 91 | 226 | 303 | 89 | 113 | 10/1/1975 | 8/10/1992 | |
| 0607 | Crack & Seat | A | 102 | 109 | 236 | 303 | 107 | 113 | 10/1/1975 | 8/8/1992 | 9/2/1995 |
| 0608 | Crack & Seat | A | 203 | 201 | 239 | 303 | 1351 | 113 | 10/1/1975 | 8/8/1992 | |
| 0659 | Crack & Seat | - | Variable | 109 | 236 | 303 | 152 | 113 | 10/1/1975 | 8/8/1992 | 9/2/1995 |
| 0660 | Crack & Seat | - | Variable | 198 | 246 | 303 | 107 | 113 | 10/1/1975 | 8/8/1992 | |
| 0661 | Rubblized | - | Variable | 290 | 239 | 303 | 107 | 113 | 10/1/1975 | 8/10/1992 | |
| 0662 | Rubblized | - | Variable | 185 | 239 | 303 | 140 | 113 | 10/1/1975 | 6/8/1992 | |
| 0663 | Rubblized | - | Variable | 272 | 241 | 303 | 114 | 113 | 10/1/1975 | 8/8/1992 | |
| 0664 | Rubblized | - | Variable | 175 | 246 | 303 | 130 | 113 | 10/1/1975 | 7/9/1992 | |
| 0665 | State | - | Variable | 117 | 229 | 303 | 117 | 113 | 10/1/1975 | 8/10/1992 | |
| 0666 | Minimum | - | - | - | 231 | 303 | 117 | 113 | 10/1/1975 | 6/9/1992 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 7 | 7 | 5 | 3 | 4 | 2 | 2 | - | 498,612 |
| 0602 | 5 | 7 | 6 | 2 | 5 | 3 | 2 | - | 498,612 |
| 0603 | 6 | 7 | 6 | 2 | 2 | 3 | 6 | 1.09 | 498,612 |
| 0604 | 6 | 6 | 6 | 3 | 2 | 3 | 6 | 1.08 | 498,612 |
| 0605 | 5 | 8 | 6 | 3 | 5 | 3 | 2 | - | 498,612 |
| 0606 | 7 | 6 | 6 | 3 | 2 | 3 | 6 | 1.10 | 497,870 |
| 0607 | 5 | 6 | 5 | 3 | 2 | 3 | 6 | 1.31 | 498,612 |
| 0608 | 7 | 10 | 6 | 3 | 2 | 3 | 6 | 1.28 | 499,354 |
| 0659 | 5 | 8 | 4 | 2 | 2 | 3 | 6 | 1.26 | 498,612 |
| 0660 | 7 | 4 | 6 | 2 | 2 | 3 | 6 | 1.18 | 500,096 |
| 0661 | 6 | 4 | 7 | 2 | 2 | 3 | 6 | 1.22 | 499,354 |
| 0662 | 6 | 6 | 6 | 2 | 2 | 2 | 6 | 1.24 | 499,354 |
| 0663 | 6 | 2 | 6 | 2 | 2 | 3 | 6 | 1.37 | 514,194 |
| 0664 | 6 | 7 | 6 | 2 | 2 | 3 | 6 | 1.18 | 500,096 |
| 0665 | 5 | 3 | 5 | 2 | 2 | 3 | 6 | 1.15 | 498,612 |
| 0666 | 6 | 5 | 6 | 2 | 5 | 3 | 2 | - | N/A |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
113= Fine-grained soils: Sandy clay.
1 mm= .039 inch
Table 68. Design and monitoring requirements for Missouri SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 290601 | Yes | Yes | Yes | Yes | - | Yes |
| 290602 | Yes | Yes | Yes | Yes | - | Yes |
| 290603 | Yes | Yes | Yes | Yes | Yes | Yes |
| 290604 | Yes | Yes | Yes | Yes | Yes | Yes |
| 290605 | Yes | Yes | Yes | Yes | - | Yes |
| 290606 | Yes | Yes | Yes | Yes | Almost | Yes |
| 290607 | Yes | Yes | Yes | Yes | Almost | Yes |
| 290608 | Yes | Yes | Yes | Yes | Yes | Yes |
| 290659 | Yes | Yes | Yes | - | - | Yes |
| 290660 | Yes | Yes | Yes | - | - | Yes |
| 290661 | Yes | Yes | Yes | - | - | Yes |
| 290662 | Yes | Yes | Yes | - | - | Yes |
| 290663 | Yes | Yes | Yes | - | - | Yes |
| 290664 | Yes | Yes | Yes | - | - | Yes |
| 290665 | Yes | Yes | Yes | - | - | Yes |
| 290666 | Yes | Yes | Yes | - | - | Yes |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 290601 | No | No | Yes | Almost | Yes | Almost | Yes | Almost | Almost | - | Yes |
| 290602 | Yes | Yes | Yes | Almost | Almost | No | Yes | Almost | Almost | - | Yes |
| 290603 | Yes | Yes | Yes | Almost | Almost | Almost | Almost | - | Almost | Yes | Yes |
| 290604 | Yes | Yes | Yes | Almost | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 290605 | Yes | Yes | Yes | Almost | Almost | No | Yes | Almost | Almost | - | Yes |
| 290606 | Yes | Yes | Yes | Almost | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 290607 | Yes | Yes | Yes | Almost | Yes | Almost | Almost | - | Yes | Yes | Yes |
| 290608 | Yes | Yes | Yes | Almost | Yes | Almost | Almost | - | Almost | Yes | Yes |
| 290659 | Yes | Yes | Yes | Almost | No | Almost | Almost | - | No | Yes | Yes |
| 290660 | Yes | Yes | Yes | Almost | No | Almost | Almost | - | Almost | Yes | Yes |
| 290661 | Yes | Yes | Yes | Almost | No | Almost | Almost | - | Almost | Yes | Yes |
| 290662 | Yes | Yes | Yes | Almost | No | Almost | Almost | - | Almost | Yes | Yes |
| 290663 | Yes | Yes | Yes | Almost | No | Almost | Almost | - | Almost | Yes | Yes |
| 290664 | Yes | Yes | Yes | Almost | No | Almost | Almost | - | Almost | Yes | Yes |
| 290665 | No | Yes | Yes | Almost | No | No | Almost | - | Almost | Yes | Yes |
| 290666 | Yes | Yes | Yes | Almost | Yes | Almost | Almost | Almost | Almost | - | Yes |
| Yes= Design criteria met. | Almost= Close to meeting design criteria. |
| N/A= Not available. | Dash (-)= Data do not apply to this cell. |
| No= Design criteria not met. | |
MISSOURI (A)
All levels of data were used to complete the summaries presented in tables 69 and 70. The information presented in table 69 that italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for the Missouri (A) site, most of the design and traffic information is not in the IMS database at this time. Therefore, it is impossible to determine if these section properties meet all of the original design parameters established for the SPS-6 experiment.
Table 70 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. All of the climatic factors have been met for this site. Unfortunately, as shown in this table, currently there is not enough information available to determine if the traffic, as-constructed design data, short-term monitoring, and long-term monitoring requirements have been met. It is very likely that not enough time has passed for all of the monitoring activities (short and long term) to be collected and loaded into the IMS database. Therefore, it is anticipated that some of these monitoring requirements will be met as these pavement sections continue to age and the information is added to the IMS database.
Table 69. Missouri (A) SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Wet, Freeze | Traffic availability: None |
| Initial pavement condition: Fair | Climatic availability: None | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| A601 | Routine | O | - | - | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A602 | Minimum | O | - | - | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A603 | Minimum | A | 102 | N/A | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A604 | Minimum* | A,O | 102 | N/A | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A605 | Maximum | A,O | - | - | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A606 | Maximum | A,O | 102 | N/A | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A607 | Crack & Seat | A | 102 | N/A | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
| A608 | Crack & Seat | A | 203 | N/A | N/A | N/A | N/A | - | 1/1/1969 | 9/3/1998 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| A601 | 0 | 0 | 1 | 0 | 1 | 0 | 0 | - | N/A |
| A602 | 0 | 0 | 1 | 0 | 1 | 0 | 0 | - | N/A |
| A603 | 0 | 0 | 1 | 0 | 1 | 0 | 0 | N/A | N/A |
| A604 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | N/A | N/A |
| A605 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | - | N/A |
| A606 | 0 | 1 | 2 | 0 | 1 | 0 | 1 | N/A | N/A |
| A607 | 0 | 0 | 1 | 0 | 1 | 0 | 0 | N/A | N/A |
| A608 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | N/A | N/A |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm: Thickness in mm.Orig. Constr.: Date of original construction.Rehab.: Date of rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
1 mm= .039 inch
Table 70. Design and monitoring requirements for Missouri (A) SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 29A601 | Yes | Yes | N/A | Yes | - | N/A |
| 29A602 | Yes | Yes | N/A | Yes | - | N/A |
| 29A603 | Yes | Yes | N/A | Yes | N/A | N/A |
| 29A604 | Yes | Yes | N/A | Yes | N/A | N/A |
| 29A605 | Yes | Yes | N/A | Yes | - | N/A |
| 29A606 | Yes | Yes | N/A | Yes | N/A | N/A |
| 29A607 | Yes | Yes | N/A | Yes | N/A | N/A |
| 29A608 | Yes | Yes | N/A | Yes | N/A | N/A |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 29A601 | Yes | No | No | No | No | No | N/A | N/A | N/A | - | N/A |
| 29A602 | Yes | No | No | No | No | No | N/A | N/A | N/A | - | N/A |
| 29A603 | Yes | No | No | No | No | No | N/A | - | N/A | N/A | N/A |
| 29A604 | No | No | No | No | No | No | N/A | - | N/A | N/A | N/A |
| 29A605 | No | No | No | No | No | No | N/A | N/A | N/A | - | N/A |
| 29A606 | Yes | Yes | No | Yes | Yes | No | N/A | - | N/A | N/A | N/A |
| 29A607 | Yes | No | No | No | No | No | N/A | - | N/A | N/A | N/A |
| 29A608 | No | No | No | No | No | No | N/A | - | N/A | N/A | N/A |
| Yes= Design criteria met. | N/A= Not available. |
| No= Design criteria not met. | Dash (–)= Data do not apply to this cell. |
OKLAHOMA
All levels of data were used to complete the summaries presented in tables 71 and 72. The information presented in table 71 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Oklahoma, the original construction date does not fall within the original design parameters established for the SPS-6 experiment. In addition, some of the restoration techniques and AC overlay thicknesses do not meet the requirements of the SPS-6 experiment.
Table 72 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, some of the climatic data meet the requirements. The traffic data meet the SPS-6 requirements. In addition, it can be noted that most of the as-constructed design data and the monitoring data for immediately before and after rehabilitation meet the requirements. In general, the long-term monitoring intervals were typically met.
Table 71. Oklahoma SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: ;Wet, No Freeze | Traffic availability: 3 years |
| Initial pavement condition: Fair | Climatic availability: 35 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | O,D | - | - | 224 | 309 | 419 | 141 | 1/1/1963 | 7/10/1992 | |
| 0602 | Minimum | O | - | - | 224 | 309 | 419 | 141 | 1/1/1963 | 8/21/1992 | |
| 0603 | Minimum | O | 102 | 102 | 229 | 309 | 386 | 141 | 1/1/1963 | 8/9/1992 | |
| 0604 | Minimum* | A,O | 102 | 97 | 229 | 309 | 386 | 141 | 1/1/1963 | 8/9/1992 | |
| 0605 | Maximum | A,O | - | - | 229 | 309 | 376 | 141 | 1/1/1963 | 8/27/1992 | |
| 0606 | Maximum | A,O | 102 | 109 | 231 | 309 | 376 | 141 | 1/1/1963 | 8/9/1992 | |
| 0607 | Crack & Seat | M,D | 102 | 117 | 229 | 309 | 386 | 141 | 1/1/1963 | 8/3/1992 | |
| 0608 | Crack & Seat | M,D | 203 | 198 | 234 | 309 | 376 | 141 | 1/1/1963 | 8/3/1992 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 4 | 6 | 6 | 2 | 6 | 2 | 3 | - | 487,376 |
| 0602 | 6 | 5 | 6 | 2 | 6 | 2 | 3 | - | 487,376 |
| 0603 | 5 | 4 | 6 | 2 | 1 | 2 | 6 | 0.74 | 304,987 |
| 0604 | 4 | 4 | 6 | 2 | 1 | 2 | 5 | 0.86 | 304,987 |
| 0605 | 6 | 6 | 6 | 2 | 6 | 2 | 3 | - | 487,768 |
| 0606 | 4 | 4 | 6 | 2 | 1 | 1 | 5 | 0.92 | 304,790 |
| 0607 | 4 | 4 | 6 | 2 | 1 | 2 | 5 | 1.08 | 304,790 |
| 0608 | 5 | 4 | 6 | 2 | 1 | 2 | 5 | 1.27 | 304,398 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm: Thickness in mm;
Orig. Constr.: Date of original construction;
Rehab.: Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
141= Fine-grained soils: Silt.
1 mm= .039 inch
Table 72. Design and monitoring requirements for Oklahoma SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 400601 | Yes | No | Yes | No | - | Yes |
| 400602 | Yes | No | Yes | Yes | - | Yes |
| 400603 | Yes | No | Yes | Yes | Yes | Yes |
| 400604 | Yes | No | Yes | Yes | Yes | Yes |
| 400605 | Yes | No | Yes | Yes | - | Yes |
| 400606 | Yes | No | Yes | Yes | Almost | Yes |
| 400607 | Yes | No | Yes | No | No | Yes |
| 400608 | Yes | No | Yes | No | Yes | Yes |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 400601 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | Almost | Almost | - | Almost |
| 400602 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | Almost | Almost | - | Almost |
| 400603 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | - | Almost | Yes | Almost |
| 400604 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | - | Almost | Almost | Almost |
| 400605 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | Almost | Almost | - | Almost |
| 400606 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | - | Almost | Almost | Almost |
| 400607 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | - | Almost | Almost | Yes |
| 400608 | Yes | Yes | Yes | Yes | Almost | Almost | Yes | - | Almost | Almost | Almost |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
PENNSYLVANIA
All levels of data were used to complete the summaries presented in tables 73 and 74. The information presented in table 73 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Pennsylvania, the PCC thicknesses and some additional material parameters did not meet the SPS-6 requirements.
Table 74 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, currently the climate, traffic, and most of the as-constructed design data requirements have been met. In addition, it can be noted that only some of the intervals immediately before and after rehabilitation meet the requirements of the SPS-6 experiment. The long-term monitoring intervals were typically met.
Table 73. Pennsylvania SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: Wet, Freeze | Traffic availability: 1 to 2 years |
| Initial pavement condition: Fair | Climatic availability: 29 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | De- assigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 262 | 303 | 254 | 141 | 9/1/1968 | 9/30/1992 | |
| 0602 | Minimum | A | - | - | 259 | 303 | 304.8 | 141 | 9/1/1968 | 9/30/1992 | |
| 0603 | Minimum | O,D | 102 | 102 | 257 | 303 | 254 | 141 | 9/1/1968 | 9/30/1992 | |
| 0604 | Minimum* | A,O,D | 102 | 109 | 262 | 303 | 254 | 141 | 9/1/1968 | 9/30/1992 | |
| 0605 | Maximum | A,O | - | - | 257 | 303 | 279.4 | 141 | 9/1/1968 | 9/17/1992 | |
| 0606 | Maximum | A,O | 102 | 114 | 257 | 303 | 228.6 | 141 | 9/1/1968 | 9/30/1992 | |
| 0607 | Crack & Seat | A,O | 102 | 112 | 257 | 303 | 264.16 | 141 | 9/1/1968 | 9/23/1992 | |
| 0608 | Crack & Seat | A | 203 | 213 | 257 | 303 | 241.3 | 141 | 9/1/1968 | 9/23/1992 | |
| 0660 | Rubblized | - | Variable | 241 | 269 | 303 | 254 | 141 | 9/1/1968 | 9/23/1992 | |
| 0661 | Rubblized | - | Variable | 665 | 254 | 303 | 279.4 | 141 | 9/1/1968 | 9/23/1992 | |
| 0662 | Crack & Seat | - | Variable | 196 | 259 | 303 | 254 | 141 | 9/1/1968 | 9/23/1992 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 8 | 7 | 5 | 2 | 4 | 0 | 2 | - | 2,146,737 |
| 0602 | 10 | 6 | 5 | 2 | 4 | 0 | 2 | - | 2,146,737 |
| 0603 | 8 | 4 | 5 | 2 | 1 | 0 | 5 | 1.07 | 2,146,737 |
| 0604 | 7 | 4 | 5 | 2 | 1 | 0 | 5 | 1.14 | 2,146,737 |
| 0605 | 10 | 7 | 5 | 2 | 4 | 0 | 2 | - | 2,146,737 |
| 0606 | 7 | 4 | 5 | 2 | 1 | 0 | 5 | 1.09 | 2,146,737 |
| 0607 | 8 | 5 | 5 | 2 | 1 | 0 | 5 | 1.04 | 2,146,737 |
| 0608 | 9 | 4 | 5 | 2 | 1 | 0 | 5 | 1.00 | 2,039,231 |
| 0660 | 9 | 3 | 4 | 2 | 0 | 0 | 5 | 0.96 | 2,146,737 |
| 0661 | 6 | 3 | 3 | 2 | 0 | 0 | 4 | 0.84 | 2,146,737 |
| 0662 | 8 | 3 | 3 | 2 | 0 | 0 | 4 | 0.91 | 2,146,737 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
141= Fine-grained soils: Silt.
1 mm= .039 inch
Table 74. Design and monitoring requirements for Pennsylvania SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 420601 | Yes | Yes | Yes | Yes | - | Almost |
| 420602 | Yes | Yes | Yes | Yes | - | Almost |
| 420603 | Yes | Yes | Yes | No | No | Almost |
| 420604 | Yes | Yes | Yes | No | Almost | Almost |
| 420605 | Yes | Yes | Yes | Yes | - | Almost |
| 420606 | Yes | Yes | Yes | Yes | Almost | Almost |
| 420607 | Yes | Yes | Yes | Yes | Almost | Almost |
| 420608 | Yes | Yes | Yes | Yes | Yes | Almost |
| 420660 | Yes | Yes | Yes | - | - | Almost |
| 420661 | Yes | Yes | Yes | - | - | Almost |
| 420662 | Yes | Yes | Yes | - | - | Almost |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 420601 | No | Yes | Yes | No | Yes | Yes | Yes | Almost | Almost | - | Yes |
| 420602 | No | Yes | Yes | No | Yes | Yes | Yes | Almost | Almost | - | Yes |
| 420603 | No | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 420604 | No | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 420605 | No | Yes | Yes | No | No | Yes | Yes | Almost | Almost | - | Yes |
| 420606 | No | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 420607 | No | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 420608 | No | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 420660 | No | Yes | Yes | No | No | Yes | Yes | - | Almost | Yes | Yes |
| 420661 | No | Yes | Yes | No | No | Yes | Yes | - | No | Yes | Yes |
| 420662 | No | Yes | Yes | No | No | Yes | Yes | - | No | Yes | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
SOUTH DAKOTA
All levels of data were used to complete the summaries presented in tables 75 and 76. The information presented in table 75 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for South Dakota, some of the AC thicknesses, all of the PCC thicknesses, and all of the traffic levels do not fall within the original design parameters established for the SPS-6 experiment.
Table 76 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, the climatic factors were almost met. In addition, most of the as-constructed design data and some of the monitoring data from immediately before and after rehabilitation meet the requirements. On average, the long-term monitoring intervals were met.
Table 75. South Dakota SPS-6 site summary.
General Site Information:
| PCC type: JRCP | Climatic zone: Wet, Freeze | Traffic availability: 1 to 2 years |
| Initial pavement condition: Fair | Climatic availability: 29 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | A | - | - | 178 | 331 | 102 | 131 | 10/1/1973 | 9/27/1992 | |
| 0602 | Minimum | A | - | - | 178 | 331 | 112 | 131 | 10/1/1973 | 8/6/1992 | |
| 0603 | Minimum | O | 102 | 112 | 180 | 331 | 112 | 148 | 10/1/1973 | 9/25/1992 | |
| 0604 | Minimum* | A,O | 102 | 112 | 180 | 331 | 91 | 148 | 10/1/1973 | 9/25/1992 | |
| 0605 | Maximum | A,O | - | - | 178 | 331 | 102 | 131 | 10/1/1973 | 8/6/1992 | |
| 0606 | Maximum | A,O | 102 | 109 | 183 | 331 | 112 | 148 | 10/1/1973 | 9/25/1992 | |
| 0607 | Crack & Seat | A | 102 | 122 | 185 | 331 | 142 | 148 | 10/1/1973 | 9/24/1992 | |
| 0608 | Crack & Seat | A | 203 | 168 | 196 | 331 | 135 | 148 | 10/1/1973 | 9/24/1992 | |
| 0660 | Crack & Seat | - | Variable | 147 | 185 | 331 | 140 | 148 | 10/1/1973 | 9/24/1992 | |
| 0661 | State | - | Variable | 117 | 185 | 331 | 140 | 148 | 10/1/1973 | 9/25/1992 | |
| 0662 | State | - | Variable | 104 | 185 | 331 | 140 | 148 | 10/1/1973 | 9/25/1992 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 7 | 5 | 4 | 2 | 4 | 0 | 2 | - | 59,683 |
| 0602 | 6 | 4 | 3 | 2 | 4 | 0 | 2 | - | 59,683 |
| 0603 | 6 | 4 | 4 | 2 | 0 | 0 | 5 | 1.09 | 58,209 |
| 0604 | 6 | 4 | 3 | 2 | 0 | 0 | 4 | 1.26 | 58,224 |
| 0605 | 7 | 4 | 3 | 2 | 3 | 0 | 2 | - | 59,683 |
| 0606 | 6 | 4 | 3 | 2 | 0 | 0 | 5 | 1.04 | 58,209 |
| 0607 | 6 | 5 | 3 | 2 | 0 | 0 | 5 | 1.02 | 58,229 |
| 0608 | 6 | 5 | 4 | 2 | 0 | 0 | 5 | 0.84 | 58,344 |
| 0660 | 6 | 5 | 3 | 2 | 0 | 0 | 5 | 0.88 | 58,209 |
| 0661 | 6 | 4 | 3 | 2 | 0 | 0 | 5 | 1.02 | 58,229 |
| 0662 | 6 | 5 | 3 | 2 | 0 | 0 | 4 | 1.05 | 58,229 |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
131= Fine-grained soils: Silty clay.
148= Fine-grained soils: Clayey silt.
1 mm= .039 inch
Table 76. Design and monitoring requirements for South Dakota SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 460601 | Almost | Yes | No | Yes | - | Almost |
| 460602 | Almost | Yes | No | Yes | - | Almost |
| 460603 | Almost | Yes | No | Yes | Almost | Almost |
| 460604 | Almost | Yes | No | Yes | Almost | Almost |
| 460605 | Almost | Yes | No | Yes | - | Almost |
| 460606 | Almost | Yes | No | Yes | Almost | Almost |
| 460607 | Almost | Yes | No | Yes | No | Almost |
| 460608 | Almost | Yes | No | Yes | No | Almost |
| 460660 | Almost | Yes | No | - | - | Almost |
| 460661 | Almost | Yes | No | - | - | Almost |
| 460662 | Almost | Yes | No | - | - | Almost |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 460601 | No | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Yes |
| 460602 | No | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Yes |
| 460603 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460604 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460605 | No | Yes | Yes | Yes | Yes | No | Almost | Almost | Almost | - | Yes |
| 460606 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460607 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460608 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460660 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460661 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| 460662 | No | Yes | Yes | Yes | Yes | No | Almost | - | Almost | Yes | Yes |
| Yes= Design criteria met. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. |
TENNESSEE
All levels of data were used to complete the summaries presented in tables 77 and 78. The information presented in table 77 that is italicized highlights information that does not meet the specifications established for this particular site and/or section. As shown, for Tennessee, a couple of AC overlay thicknesses and some of the rehabilitation techniques do not meet the original design parameters established for the SPS-6 experiment.
Table 78 summarizes the site and monitoring requirements that were and were not met based on the IMS data requests for this project. As shown in this table, currently there is not enough information available to determine if the traffic data requirements have been met. In general, the as-constructed design data almost met the requirements. All of the monitoring requirements for immediately before and after rehabilitation were met. Also, because this section is still relatively new, only some of the long-term monitoring distress requirements have been met. It is very likely that not enough time has passed for all of the long-term monitoring activities to be collected and loaded into the IMS database. Therefore, it is anticipated that the long-term monitoring requirements will be met as these pavement sections continue to age.
Table 77. Tennessee SPS-6 site summary.
General Site Information:
| PCC type: JPCP | Climatic zone: Wet, No Freeze | Traffic availability: None |
| Initial pavement condition: Fair | Climatic availability: 33 years | |
Site Information:
| | Restoration Technique | Pavement Structure | Date |
| ID | Design | Compliance | AC Overlay Thick. mm | PCC | Base | Subgrade Type | Orig. Constr. | Rehab. | Deassigned |
| Design | Actual | Thick. mm | Type | Thick. mm |
| 0601 | Routine | O,D | - | - | 229 | 339 | 152 | 204 | 1/1/1966 | 6/7/1996 | |
| 0602 | Minimum | O | - | - | 226 | 339 | 152 | 204 | 1/1/1966 | 6/7/1996 | |
| 0603 | Minimum | D | 102 | 112 | 229 | 339 | 191 | 102 | 1/1/1966 | 6/8/1996 | |
| 0604 | Minimum* | A,O,D | 102 | 107 | 229 | 339 | 168 | 114, 119 | 1/1/1966 | 6/7/1996 | |
| 0605 | Maximum | A,O | - | - | 229 | 339 | 191 | 102 | 1/1/1966 | 6/8/1996 | |
| 0606 | Maximum | A,O,D | 102 | 104 | 241 | 339 | 191 | 102 | 1/1/1966 | 6/7/1996 | |
| 0607 | Crack & Seat | A,D | 102 | 112 | 224 | 339 | 168 | 114 | 1/1/1966 | 6/8/1996 | |
| 0608 | Crack & Seat | A,D | 203 | 221 | 218 | 339 | 168 | 114 | 1/1/1966 | 6/8/1996 | |
| 0661 | State | - | Variable | 211 | 229 | 339 | 168 | 114 | 1/1/1966 | 6/8/1996 | |
| 0662 | State | - | Variable | 218 | 226 | 339 | 168 | 114 | 1/1/1966 | 6/8/1996 | |
Monitoring Information:
| | Number of Monitoring Data Collection Dates | Profile | Traffic |
| | | Distress | | | Initial AC IRI, m/km | Average ESALs |
| ID | IRI | FWD | Manual | PASCO | Faulting | Friction | Rutting |
| 0601 | 3 | 2 | 3 | 0 | 2 | 1 | 1 | - | N/A |
| 0602 | 3 | 3 | 2 | 0 | 2 | 1 | 1 | - | N/A |
| 0603 | 3 | 2 | 3 | 0 | 1 | 1 | 1 | 0.71 | N/A |
| 0604 | 3 | 3 | 3 | 0 | 1 | 1 | 1 | 0.66 | N/A |
| 0605 | 2 | 3 | 2 | 0 | 2 | 1 | 1 | - | N/A |
| 0606 | 5 | 2 | 3 | 0 | 1 | 1 | 1 | 0.83 | N/A |
| 0607 | 3 | 3 | 3 | 0 | 1 | 1 | 1 | 0.68 | N/A |
| 0608 | 4 | 3 | 3 | 0 | 1 | 1 | 1 | 0.75 | N/A |
| 0661 | 2 | 2 | 3 | 0 | 1 | 1 | 0 | 0.76 | N/A |
| 0662 | 2 | 2 | 3 | 0 | 1 | 1 | 1 | 0.75 | N/A |
General Notes:
N/A: Data are not in the IMS database yet.
Dash (-): Does not apply to this cell.
Italicized letters and numbers represent section information that was not acquired within the experiment specifications.
Abbreviations:
Thick. mm= Thickness in mm;
Orig. Constr.= Date of original construction;
Rehab.= Rehabilitation.
Additional Notes:
*AC overlay has been sawed and sealed.
A= All requirements satisfied, M= Most requirements satisfied, O= Optional treatments applied, and D= "Do not perform" treatments applied.
102= Fine-grained soils: Lean inorganic clay.
114= Fine-grained soils: Sandy lean clay.
119= Fine-grained soils: Sandy clay with gravel.
204= Coarse-grained soils: Poorly graded sand with gravel.1 mm= .039 inch
Table 78. Design and monitoring requirements for Tennessee SPS-6 site.
Site Information:
| Section | Climate | Traffic | As Constructed |
| Moisture | Temperature | Compliance | AC Thick. | PCC Thick. |
| 470601 | Yes | Almost | N/A | No | - | Almost |
| 470602 | Yes | Almost | N/A | Yes | - | Almost |
| 470603 | Yes | Almost | N/A | No | Almost | Almost |
| 470604 | Yes | Almost | N/A | No | Yes | Almost |
| 470605 | Yes | Almost | N/A | Yes | - | Almost |
| 470606 | Yes | Almost | N/A | No | Yes | Almost |
| 470607 | Yes | Almost | N/A | No | Almost | Almost |
| 470608 | Yes | Almost | N/A | No | Almost | Almost |
| 470661 | Yes | Almost | N/A | - | - | Almost |
| 470662 | Yes | Almost | N/A | - | - | Almost |
Monitoring Information:
| Section | Monitoring Immediately Before Rehabilitation | Monitoring Immediately After Rehabilitation | Long-Term Monitoring |
| Distress | FWD | Profile | Distress | FWD | Profile | Distress | Faulting | FWD | Rutting | Profile |
| 470601 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | N/A | N/A | - | Yes |
| 470602 | Yes | Yes | Yes | Yes | Yes | Almost | No | N/A | N/A | - | Yes |
| 470603 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | N/A | N/A | Yes |
| 470604 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | N/A | N/A | Yes |
| 470605 | Yes | Yes | Yes | Yes | Yes | Almost | No | N/A | N/A | - | No |
| 470606 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | N/A | N/A | Yes |
| 470607 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | N/A | N/A | No |
| 470608 | Yes | Yes | Yes | Yes | Yes | Almost | Almost | - | N/A | N/A | Yes |
| 470661 | Yes | Yes | No | Yes | Yes | Almost | Almost | - | N/A | N/A | Yes |
| 470662 | Yes | Yes | No | Yes | Yes | Almost | Almost | - | N/A | N/A | Yes |
| Yes= Design criteria met. | N/A= Not available. | No= Design criteria not met. |
| Almost= Close to meeting design criteria. | Dash (-)= Data do not apply to this cell. | |