Rehabilitation of Asphalt Concrete Pavements: Initial Evaluation of the SPS-5 Experiment—Final Report
APPENDIX B. CONSTRUCTION DATA SUMMARY
Appendix B contains a summary of the construction data available for each project as of the approximate time of this report, which was 1999-2000. Thickness data were from three sources. The first source was the TST_L05B table, which contained the values most representative of the material that was actually placed on the test section and the pre-existing pavement structure. The second was the SPS5_LAYER table, which included thicknesses that should be the same as those provided in the TST_L05B table. However, in most of the data shown, these thicknesses were not the same. The third source was the SPS5_LAYER_ THICKNESS table. These data were obtained from elevation measurements taken on the projects after the placement of each layer of overlay.
Table 95. Summary of construction data for Alabama.
| Alabama (1) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 563 | 564 |
| Required Thickness |
| AC OVERLAY (mm) |
0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | |
| MILLING (mm) |
0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | |
| L05B Thickness |
| AC OVERLAY (mm) |
| MILLING (mm) |
| SPS Construction Thickness |
| AC OVERLAY (mm) |
| 33 | 102 | 112 | 36 | 76 | 142 | 145 | 81 | 36 | 28 |
| Rod & Level |
| AC OVERLAY (mm) |
| 33 | 100 | 110 | 35 | 52 | 123 | 114 | 45 | | 30 |
| MILLING (mm) | | | | | | 25 | 18 | 29 | 35 | 36 | |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| 8 | 9 | 10 | 9 | 6 | 7 | 4 | 5 | | 7 |
| MILLING (mm) |
| | | | | 7 | 7 | 5 | 8 | 6 | |
| Rod & Level Min |
| AC OVERLAY (mm) |
| 18 | 84 | 89 | 18 | 41 | 104 | 104 | 33 | | 15 |
| MILLING (mm) |
| | | | | 10 | 3 | 20 | 18 | 18 | |
| Rod & Level Max |
| AC OVERLAY (mm) |
| 51 | 127 | 137 | 56 | 64 | 137 | 122 | 58 | | 51 |
| MILLING (mm) |
| | | | | 43 | 30 | 41 | 56 | 48 | |
| MILLING (mm) |
| | | | | 42 | 32 | 23 | 25 | 33 | 30 |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 41 | 64 | 76 | 43 | 64 | 89 | 79 | 56 | 46 | 38 |
| AC Material Requirements |
| Hveem stability (minimum 37)Air Voids 3-5 % |
| 3.9 | 4.2 | 3.6 | 3.6 | 3.6 | 3.6 | 4.2 | 4.2 | 3.6 | 3.9 |
| Virgin Mix |
| Aggregate Pass #4<40% |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 96. Summary of construction data for Arizona.
| Arizona (4) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 559 | 560 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 69 | 119 | 122 | 71 | 132 | 173 | 165 | 99 | 152 | 56 |
| MILLING (mm) | | 23 | 20 | 18 | 23 | 48 | 66 | 69 | 71 | 86 | 23 |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 69 | 119 | 122 | 71 | 43 | 104 | 104 | 38 | 76 | 56 |
| Rod & Level |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILLING (mm) |
| MILLING (mm) | | 27 | 18 | 27 | 33 | 72 | 69 | 69 | 64 | 99 | 25 |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 64 | 76 | 74 | 74 | 74 | 81 | 76 | 71 | 109 | 66 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | 64 | | | 57 | | | | | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 53 | 53 | | | | | | 53 | 53 | 53 |
Note: The number after the state name is the state’s numeric code in the LTPP date base.
Table 97. Summary of construction data for California.
| California (6) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 559 | 560 | 561 | 562 | 563 | 564 | 565 | 566 | 567 | 568 | 569 | 570 | 571 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | | | | | | | | | | | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | | | | | | | | | | | | |
| L05B Thickness |
| AC OVERLAY (mm) | 46 | 76 | 166 | 146 | 91 | 109 | 170 | 168 | 112 | 208 | 109 | 107 | 112 | 102 | 109 | 109 | 109 | 102 | 152 | 183 | 183 | 248 |
| MILLING (mm) | | 30 | 38 | 36 | 30 | 43 | 48 | 46 | 51 | 76 | 58 | 58 | 58 | 58 | 66 | 58 | 58 | 58 | 58 | 66 | 91 | 91 |
| SPS Construction Thickness |
| AC OVERLAY (mm) | 46 | 76 | 166 | 145 | 91 | 109 | 170 | 114 | 112 | 152 | 109 | 107 | 107 | 102 | 102 | 109 | 109 | 102 | 152 | 183 | 183 | 244 |
| Rod & Level |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILLING (mm) |
| MILLING (mm) |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | 64 | 69 | 107 | 102 | 71 | 81 | 69 | 74 | 71 | 122 | 0 | 71 | 71 | 81 | 89 | 74 | 76 | 71 | 157 | 53 | 51 | 48 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | 48 | 48 | 48 | | | | | 48 | | | | | | | | | | | | | | |
Note: The number after the state name is the state’s numeric code in the LTPP date base.
Table 98. Summary of construction data for Colorado.
| Colorado(8) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 559 | 560 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | |
| L05B Thickness |
| AC OVERLAY (mm) | 33 | 97 | 137 | 147 | 81 | 112 | 173 | 201 | 107 | 168 | 155 |
| MILLING (mm) | 0 | 0 | 0 | 0 | 0 | 51 | 51 | 71 | 51 | 0 | 0 |
| SPS Construction Thickness |
| AC OVERLAY (mm) | 33 | 97 | 145 | 147 | 81 | 94 | 175 | 201 | 109 | 175 | 157 |
| Rod & Level |
| AC OVERLAY (mm) | | 89 | 135 | 154 | 74 | 65 | 149 | 132 | 65 | 172 | 151 |
| MILLING (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 13 | 18 | 17 | 21 | 28 | 19 | 25 | 16 | 30 | 20 |
| MILLING (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) | | 66 | 97 | 94 | 0 | 0 | 97 | 0 | 20 | 76 | 117 |
| MILLING (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) | | 112 | 196 | 180 | 109 | 102 | 188 | 168 | 97 | 234 | 196 |
| MILLING (mm) |
| MILLING (mm) | | | | | | 52 | 52 | 55 | 52 | | |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | 30 | 79 | 89 | 107 | 74 | 64 | 71 | 84 | 64 | 114 | 64 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | | | | | 60 | | 62 | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 58 | 58 | | | | | 58 | 58 | | |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 99. Summary of construction data for Florida.
| Florida (12) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 560 | 561 | 562 | 563 | 564 | 565 | 566 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | | | | | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | | | | | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 64 | 127 | 130 | 51 | 76 | 165 | 178 | 107 | | | | | | | |
| MILLING (mm) | | 38 | | | | 36 | | | 64 | | | | | | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 53 | 135 | 122 | 48 | 102 | 168 | 180 | 107 | | | | | | | |
| Rod & Level |
| AC OVERLAY (mm) | | 50 | 134 | 123 | 50 | 65 | 111 | 113 | 65 | | | | | | | |
| MILLING (mm) | . | . | . | . | | 35 | 55 | 67 | 42 | | | | | | | |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 9 | 7 | 8 | 4 | 4 | 6 | 7 | 5 | | | | | | | |
| MILLING (mm) | . | . | . | . | | 6 | 5 | 4 | 10 | | | | | | | |
| Rod & Level Min |
| AC OVERLAY (mm) | | 25 | 112 | 102 | 38 | 58 | 102 | 94 | 53 | | | | | | | |
| MILLING (mm) | . | . | . | . | | 20 | 46 | 61 | 20 | | | | | | | |
| Rod & Level Max |
| AC OVERLAY (mm) | | 61 | 150 | 145 | 58 | 74 | 122 | 124 | 71 | | | | | | | |
| MILLING (mm) | . | . | . | . | | 43 | 66 | 76 | 71 | | | | | | | |
| MILLING (mm) | | 22 | | 11 | 25 | 69 | 62 | 70 | 72 | | | | | | | |
| Lift Thicknessess |
| Maximum Lift Thickness =75mm | | 38 | 69 | 58 | 38 | 81 | 76 | 84 | 53 | | | | | | | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | | | 79 | | 60 | | 69 | | | | | | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 72 | 62 | | | | | 62 | 72 | | | | | | | |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 100. Summary of construction data for Georgia.
| Georgia (13) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 560 | 561 | 562 | 563 | 564 | 565 | 566 | 567 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | | | | | | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | | | | | | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 41 | 130 | 135 | 51 | 107 | 160 | 170 | 97 | 56 | 74 | 89 | 56 | 58 | 127 | 137 | |
| MILLING (mm) | | 30 | 38 | 41 | 46 | 74 | 53 | 53 | 58 | 30 | 20 | 25 | 76 | 58 | 25 | 56 | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 23 | 127 | 130 | 41 | 99 | 168 | 175 | 99 | | | | | | | | |
| Rod & Level |
| AC OVERLAY (mm) | | 23 | 125 | 128 | 42 | 48 | 119 | 123 | 43 | | | | | | | | |
| MILLING (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 8 | 4 | 7 | 9 | 4 | 15 | 5 | 6 | | | | | | | | |
| MILLING (mm) | . | . | . | . | | 52 | 47 | 49 | 57 | | | | | | | | |
| Rod & Level Min |
| AC OVERLAY (mm) | | 5 | 119 | 119 | 33 | 43 | 109 | 109 | 30 | | | | | | | | |
| MILLING (mm) | . | . | . | . | | 7 | 12 | 3 | 6 | | | | | | | | |
| Rod & Level Max |
| AC OVERLAY (mm) | | 36 | 132 | 142 | 81 | 58 | 185 | 132 | 51 | | | | | | | | |
| MILLING (mm) | . | . | . | . | | 41 | 0 | 41 | 48 | | | | | | | | |
| MILLING (mm) | | | 18 | 27 | 30 | 61 | 38 | 65 | 41 | | | | | | | | |
| Lift Thicknessess |
| Maximum Lift Thickness =75mm | | 28 | 64 | 58 | 46 | 64 | 114 | 114 | 71 | | | | | | | | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | | | | | 64 | | 66 | | | | | | | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 101. Summary of construction data for Maine.
| Maine(23) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 559 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | |
| L05B Thickness |
| AC OVERLAY (mm) | | 91 | 140 | 145 | 69 | 104 | 198 | 173 | 97 | |
| MILLING (mm) | | | | | | 38 | 43 | 30 | 38 | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 86 | 142 | 142 | 61 | 102 | 183 | 175 | 94 | |
| Rod & Level |
| AC OVERLAY (mm) | | 91 | 140 | 144 | 69 | 54 | 133 | 121 | 52 | |
| MILLING (mm) | . | . | . | . | | 50 | 57 | 52 | 43 | |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 9 | 9 | 10 | 9 | 6 | 6 | 6 | 5 | |
| MILLING (mm) | . | . | . | . | | 7 | 7 | 5 | 6 | |
| Rod & Level Min |
| AC OVERLAY (mm) | | 76 | 122 | 122 | 51 | 41 | 122 | 107 | 36 | |
| MILLING (mm) | . | . | . | . | | 30 | 46 | 41 | 30 | |
| Rod & Level Max |
| AC OVERLAY (mm) | | 114 | 155 | 165 | 84 | 66 | 145 | 140 | 66 | |
| MILLING (mm) | . | . | . | . | | 66 | 76 | 61 | 56 | |
| MILLING (mm) | | | | | | 43 | 47 | 37 | 38 | |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 61 | 58 | 58 | 38 | 58 | 89 | 81 | 58 | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | 45 | 52 | | 46 | 52 | 48 | 44 | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 47 | 39 | | | | | 39 | 39 | |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 102. Summary of construction data for Maryland.
| Maryland(24) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 559 | 560 | 561 | 562 | 563 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | | | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | | | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 53 | 135 | 135 | 53 | 91 | 191 | 168 | 97 | | | | | |
| MILLING (mm) | | | | | | 38 | 36 | 36 | 38 | | | | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 53 | 124 | 114 | 51 | 91 | 188 | 140 | 89 | | | | | |
| Rod & Level |
| AC OVERLAY (mm) | | 46 | 124 | 116 | 48 | 55 | 108 | 139 | 45 | | | | | |
| MILLING (mm) | | | | | | | 45 | | 44 | | | | | |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 7 | 8 | 9 | 6 | 5 | 6 | 6 | 4 | | | | | |
| MILLING (mm) | | | | | | | 9 | | 8 | | | | | |
| Rod & Level Min |
| AC OVERLAY (mm) | | 28 | 109 | 97 | 36 | 46 | 97 | 127 | 33 | | | | | |
| MILLING (mm) | | | | | | | 33 | | 25 | | | | | |
| Rod & Level Max |
| AC OVERLAY (mm) | | 58 | 140 | 140 | 64 | 66 | 124 | 150 | 51 | | | | | |
| MILLING (mm) | | | | | | | 71 | | 64 | | | | | |
| MILLING (mm) | | | | | | 39 | 39 | 39 | 39 | | | | | |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 61 | 61 | 66 | 64 | 64 | 64 | 57 | 64 | | | | | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | | 41 | 49 | | | | | | | | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 103. Summary of construction data for Minnesota.
| Minnesota (27) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 559 | 560 | 561 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 61 | | | 48 | | 142 | | | | | |
| MILLING (mm) |
| SPS Construction Thickness |
| AC OVERLAY (mm) |
| Rod & Level |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILLING (mm) |
| MILLING (mm) |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 104. Summary of construction data for Mississippi.
| Mississippi(28) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 560 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | |
| L05B Thickness |
| AC OVERLAY (mm) | | 51 | 117 | 124 | 51 | | | | | |
| MILLING (mm) | | 0 | 0 | 0 | 0 | | | | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 51 | 127 | 127 | 51 | 80 | 165 | 165 | 89 | |
| Rod & Level |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| MILLING (mm) | | | | | | 38 | 38 | 38 | 38 | |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 56 | 51 | 51 | 51 | 51 | 51 | 51 | 51 | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% |
| RAP |
| TOTAL AC |
| NEW AC | | 4 | 4 | | | | | 4 | 4 | |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL | | 70 | 70 | | | | | 70 | 70 | |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 67 | 67 | | | | | 67 | 67 | |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Tab1e 105. Summary of construction data for Missouri.
| Missouri(29) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 |
| L05B Thickness |
| AC OVERLAY (mm) |
| MILLING (mm) |
| SPS Construction Thickness |
| AC OVERLAY (mm) |
| Rod & Level |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILLING (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILLING (mm) |
| MILLING (mm) |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 106. Summary of construction data for Montana.
| Montana (30) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 560 | 561 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 66 | 117 | 142 | 51 | 107 | 183 | 180 | 114 | | |
| MILLING (mm) | | 20 | 28 | 33 | 15 | 69 | 71 | 71 | 66 | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 66 | 117 | 142 | 51 | 107 | 191 | 180 | 114 | | |
| Rod & Level |
| AC OVERLAY (mm) | | 27 | 101 | 92 | 37 | 28 | 95 | 89 | 28 | | |
| MILL REPLACEMENT (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 8 | 10 | 10 | 9 | 9 | 9 | 11 | 8 | | |
| MILL REPLACEMENT (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) | | 10 | 79 | 74 | 13 | 13 | 74 | 51 | 13 | | |
| MILL REPLACEMENT (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) | | 46 | 119 | 127 | 64 | 48 | 122 | 117 | 46 | | |
| MILL REPLACEMENT (mm) |
| MILLING (mm) | | 25 | 25 | 25 | 25 | 79 | 77 | 77 | 76 | | |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 61 | 94 | 89 | 64 | 74 | 94 | 94 | 71 | | |
| AC Material Requirements |
| Hveem stability (minimum 37)Air Voids 3-5 % |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | 51 | | | 55 | | | | | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 51 | 51 | | | | | 51 | 51 | | |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 107. Summary of construction data for New Jersey.
| New JerseY (34) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 509 | 560 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | | |
| L05B Thickness |
| AC OVERLAY (mm) | | 48 | 119 | 119 | 46 | 107 | 198 | 198 | 109 | | |
| MILLING (mm) | | 0 | 0 | 0 | 0 | 51 | 51 | 51 | 51 | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 51 | 127 | 127 | 127 | 102 | 178 | 178 | 102 | | |
| Rod & Level |
| AC OVERLAY (mm) | | 43 | 114 | 118 | 53 | 49 | 56 | 123 | 41 | | |
| MILL REPLACEMENT (mm) | | | | | | 54 | 56 | 55 | 64 | | |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 12 | 9 | 8 | 9 | 6 | 6 | 14 | 6 | | |
| MILL REPLACEMENT (mm) | | | | | | 9 | 10 | 8 | 11 | | |
| Rod & Level Min |
| AC OVERLAY (mm) | | 18 | 99 | 102 | 28 | 28 | 43 | 81 | 23 | | |
| MILL REPLACEMENT (mm) | | | | | | 28 | 36 | 36 | 48 | | |
| Rod & Level Max |
| AC OVERLAY (mm) | | 69 | 132 | 137 | 76 | 61 | 66 | 156 | 51 | | |
| MILL REPLACEMENT (mm) | | | | | | 69 | 89 | 86 | 99 | | |
| MILLING (mm) | | | | | | 74 | 53 | 58 | 64 | | |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 61 | 89 | 102 | 64 | 76 | 97 | 102 | 76 | | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | 53 | 55 | | | 61 | 52 | | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 108. Summary of construction data for New Mexico.
| New Mexico(35) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 |
| L05B Thickness |
| AC OVERLAY (mm) |
| MILLING (mm) |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 56 | 107 | 117 | 64 | 109 | 188 | 188 | 107 |
| Rod & Level |
| AC OVERLAY (mm) | 48 | 56 | 107 | 117 | 63 | 55 | 133 | 132 | 53 |
| MILL REPLACEMENT (mm) | | | | | | 54 | 56 | 56 | 53 |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | 6 | 12 | 11 | 11 | 9 | 4 | 5 | 6 | 6 |
| MILL REPLACEMENT (mm) | | | | | | 4 | 5 | 5 | 6 |
| Rod & Level Min |
| AC OVERLAY (mm) | 33 | 33 | 86 | 91 | 48 | 48 | 122 | 122 | 33 |
| MILL REPLACEMENT (mm) | | | | | | 46 | 46 | 46 | 33 |
| Rod & Level Max |
| AC OVERLAY (mm) | 61 | 79 | 127 | 137 | 79 | 66 | 145 | 147 | 64 |
| MILL REPLACEMENT (mm) | | | | | | 66 | 66 | 69 | 64 |
| MILLING (mm) | 51 | | | | | 51 | 51 | 64 | 51 |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | 76 | 76 | 102 | 76 | 64 | 76 | 76 | 76 | 76 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | 49 | | 59 | | 59 | 59 | |
| RAP |
| TOTAL AC |
| NEW AC | | 5 | 5 | | | | | 5 | 5 |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL | | 45 | 45 | | | | | 45 | 45 |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 43 | 43 | | | | | 43 | 43 |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 109. Summary of construction data for Oklahoma.
| Oklahoma (40) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 | 560 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 | |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 | |
| L05B Thickness |
| AC OVERLAY (mm) |
| MILLING (mm) |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 46 | 112 | 119 | 43 | 99 | 163 | 147 | 79 | |
| Rod & Level |
| AC OVERLAY (mm) | | 46 | 112 | 119 | 43 | 99 | 163 | 146 | 78 | |
| MILL REPLACEMENT (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 8 | 13 | 13 | 7 | 13 | 11 | 13 | 9 | |
| MILL REPLACEMENT (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) | | 25 | 79 | 79 | 20 | 74 | 145 | 124 | 56 | |
| MILL REPLACEMENT (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) | | 64 | 140 | 142 | 56 | 124 | 188 | 170 | 97 | |
| MILL REPLACEMENT (mm) | | | | | | 41 | 30 | 36 | 43 | |
| MILLING (mm) |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 64 | 89 | 89 | 64 | 102 | 102 | 102 | 102 | |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | 42 | 47 | | | 42 | 34 | | |
| RAP |
| TOTAL AC |
| NEW AC |
| % AC OF SALVAGED MIX | | 1 | 1 | | | | | 1 | 1 | |
| % NEW AGG.MATERIAL | | 70 | 70 | | | | | 70 | 70 | |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 59 | 59 | | | | | 59 | 59 | |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 110. Summary of construction data for Texas.
| Texas(48) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 |
| L05B Thickness |
| AC OVERLAY (mm) | | 56 | 135 | 135 | 51 | 99 | 178 | 185 | 109 |
| MILLING (mm) | | 0 | 0 | 0 | 0 | | | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 58 | 124 | 124 | 97 | 114 | 175 | 168 | 102 |
| Rod & Level |
| AC OVERLAY (mm) | | 58 | 123 | 122 | 59 | 59 | 120 | 116 | 54 |
| MILL REPLACEMENT (mm) | | | | | | 56 | 55 | 53 | 47 |
| Rod & Level Std Dev |
| AC OVERLAY (mm) | | 8 | 19 | 9 | 10 | 7 | 7 | 7 | 11 |
| MILL REPLACEMENT (mm) | | | | | | 7 | 6 | 6 | 5 |
| Rod & Level Min |
| AC OVERLAY (mm) | | 43 | 0 | 102 | 30 | 46 | 99 | 102 | 0 |
| MILL REPLACEMENT (mm) | | | | | | 41 | 38 | 43 | 33 |
| Rod & Level Max |
| AC OVERLAY (mm) | | 74 | 145 | 145 | 79 | 76 | 135 | 127 | 71 |
| MILL REPLACEMENT (mm) | | | | | | 71 | 76 | 64 | 66 |
| MILLING (mm) | | | | | | 44 | 46 | 37 | 43 |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 58 | 53 | 48 | 58 | 58 | 56 | 48 | 53 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | | | | | 55 | | 55 |
| RAP |
| TOTAL AC |
| NEW AC | | 3 | 3 | | | | | 3 | 3 |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL | | 65 | 65 | | | | | 65 | 65 |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 71 | 71 | | | | | 71 | 71 |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 111. Summary of construction data for Alberta.
| Alberta (81) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 |
| L05B Thickness |
| AC OVERLAY (mm) | | 53 | 127 | 122 | | 94 | 163 | 178 | 84 |
| MILLING (mm) | | 0 | | 0 | 0 | 41 | 56 | 76 | 64 |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 53 | 127 | 122 | 53 | 94 | 160 | 178 | 84 |
| Rod & Level |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| MILLING (mm) | | | | | | 56 | 53 | 48 | 50 |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 58 | 74 | 76 | 58 | 61 | 71 | 74 | 61 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % |
| Virgin Mix |
| Aggregate Pass #4<40% | | | | 64 | | | | 64 | |
| RAP |
| TOTAL AC |
| NEW AC | | 4 | 4 | | | | | 4 | 4 |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL | | 70 | 70 | | | | | 70 | 70 |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 64 | 64 | | | | | 64 | 64 |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
Table 112. Summary of construction data for Manitoba.
| Alberta (81) | 501 | 502 | 503 | 504 | 505 | 506 | 507 | 508 | 509 |
| Required Thickness |
| AC OVERLAY (mm) | 0 | 51 | 127 | 127 | 51 | 51 | 127 | 127 | 51 |
| MILLING (mm) | 0 | <25.4 | <25.4 | <25.4 | <25.4 | 38–50 | 38–50 | 38–50 | 38–50 |
| L05B Thickness |
| AC OVERLAY (mm) | | 69 | 124 | 142 | | 81 | 165 | 165 | 94 |
| MILLING (mm) | | | | | 0 | | | | |
| SPS Construction Thickness |
| AC OVERLAY (mm) | | 64 | 140 | 127 | 51 | 89 | 165 | 165 | 89 |
| Rod & Level |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Std Dev |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Min |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| Rod & Level Max |
| AC OVERLAY (mm) |
| MILL REPLACEMENT (mm) |
| MILLING (mm) | | | | | | 38 | 38 | 38 | 38 |
| Lift Thicknessess |
| Maximum Lift Thickness<=75mm | | 51 | 51 | 51 | 51 | 51 | 38 | 38 | 51 |
| AC Material Requirements |
| Hveem stability (minimum 37) |
| Air Voids 3-5 % | | 4.5 | 4.5 | 3.9 | 3.9 | 3.9 | 3.9 | 4.5 | 4.5 |
| Virgin Mix |
| Aggregate Pass #4<40% |
| RAP |
| TOTAL AC |
| NEW AC | | 5 | 5 | | | | | 5 | 5 |
| % AC OF SALVAGED MIX |
| % NEW AGG.MATERIAL | | 70 | 70 | | | | | 70 | 70 |
| % RAP |
| New Aggregate |
| Aggregate Pass #4 <40% | | 62 | 62 | | | | | 62 | 62 |
Note: The number after the state name is the state’s numeric code in the LTPP data base.
|